摘要
神头一电厂苏制Eп-670/140型锅炉,高温过热器管排及导汽管出现超温频繁爆破,经反复试验研究,发现了导致爆管的根本原因,经采取相应改进措施,取得良好效果。本文通过大量的试验数据和试验曲线,分析得出了结论。
The hilgh-temperature superheater pipelines and conduit pipes of the Soviet-made En -670/140 Boiler frequenty bursted because of superhigh temperature. By the way of repeatedly experiments and research, the fundamental causes are found, the relevant measures are taken,and the problem is solved satisfacf orily.
出处
《电力学报》
1998年第1期55-61,共7页
Journal of Electric Power
关键词
锅炉
爆管
试验研究
高温过热器
发电厂
hursting of boiler pipe
experimental research
measures of improvement