期刊文献+

V12绘图仪主逻辑板常见故障分析 被引量:1

The common trouble shooting for the main logic circuit of V12 plotter
下载PDF
导出
摘要 V12绘图仪是目前地震勘探仪器最常用的辅助绘图设备之一,也是野外施工现场重要的质量监控设备。本文对该设备主逻辑板电路进行了较为详尽地分析,列举了电路常见故障并给出了相应的故障排除方法,具有很强的实用性和可操作性。 Designed by ISG(Imaging Systems Group Inc. ), the V12 plotter is one of the most commonly used auxiliary plot equipments in the present seismic exploration and also is an important on-site OC equipment. After a more detailed analysis on the main logic circuit of this device, the paper listed some common circuit faults and the corresponding troubleshooting. Then practical solutions are proposed.
出处 《物探装备》 2009年第5期311-315,318,共6页 Equipment for Geophysical Prospecting
关键词 V12绘图仪 主逻辑板 故障分析 V12 plotter, main logic, troubleshooting
  • 相关文献

参考文献6

  • 1iSYS公司.V12 Thermal plotter hardware manual(V 2.0).2000.
  • 2吴秀琴,秦明辉.V12绘图仪内部接口电路分析及其故障排除[J].物探装备,2006,16(4):277-281. 被引量:3
  • 3Sercel公司.428XL en428install电子文档.2007.
  • 4MICROCHIP公司.DS30605C电子文档.
  • 5CYPRESS公司.Document#:38-05408,Document#:38-06011电子文档.
  • 6ALTERA公司.MAX 7000 Programmable Logic Device Family Data Sheet电子文档.

二级参考文献2

  • 1[1]SYS 公司.V12 Thermal Plotter Hardware Manual.2000
  • 2[2]OYO 公司.GS 612P Thermal Plotter Operation Manual.1999