期刊文献+

不同喷淋层投运方式下脱硫塔内流场特性的数值研究 被引量:9

Numerical Simulation of Flow Field Inside WFGD Under Different Spray Levels Operation
下载PDF
导出
摘要 采用数值计算方法,对900 MW机组湿法烟气脱硫系统的喷淋塔内流场进行了数值模拟,着重考察了不同喷淋层的投运方式对塔内流场的影响.研究结果表明,在烟气量为4.45566×106m3/h,塔径为18.5m,3层喷淋,层间距2 m时,90MW机组的湿法烟气脱硫系统的喷淋塔内阻力约为1.1 KPa,与现场运行数据较为吻合.模拟结果表明,不同喷淋层的投运方式对流场影响较大. Adopting the numerical calculation method, the flow field of 900 MW wet flue gas desulfurization(WFGD) spraying scrubber is simulated, and how spray levels affect the scrubber resistance is obtained. The results show, for flue gas flow 4.455 660 m^3/h, scrubber diameter 18.5 m, three spray levels and level spacing interval 2 m, the resistance value of the 900 MW wet flue gas desulfurization spraying scrubber is about 1 100 Pa,which almost accords with the operation data in field. The flow field is significantly affected by using different spray levels.
出处 《上海电力学院学报》 CAS 2009年第5期413-417,共5页 Journal of Shanghai University of Electric Power
基金 上海市科委科技攻关项目(09DZ1203903) 上海市引进技术的吸收与创新计划的资助(07XI-039)
关键词 湿法烟气脱硫 喷淋层 数值模拟 wet flue gas desulphurization spray level numerical simulation