不同螺距对40层螺旋CT冠状动脉成像质量的影响
摘要
多层螺旋CT(MSCT)冠状动脉成像图像受多种因素影响,其中螺距是影响扫描的重要因素,本文通过对不同螺距条件下扫描图像的对比,旨在研究螺距对40层螺旋CT冠状动脉成像检查图像质量的影响。
出处
《新疆医学》
2009年第9期91-95,共5页
Xinjiang Medical Journal
参考文献7
-
1Mahadevappa M, Dianna D C, AAPM/RSNA Physics Tutorial for Residents. Radiographics, 2007 ; 27 ( 5 ) : 1495 - 1509.
-
2Choi HS, Choi BW, Choe Ko, et al. Pitfalls, artifacts, and remedies in multi- detector row CT coronary angiography. Radiographics,2004 ;24:787 - 800.
-
3Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease. Report of the AdHoc Committee for Grading of Coronary Artery Disease, Council on CardiovascularSurgery. Circulation, 1975 ;51 (4 Suppl) :5 -40.
-
4周泽俊,胡永胜,高斌,巢惠民.多层螺旋CT螺距、层厚和重建间隔关系及对图像质量影响[J].中国医疗设备,2008,23(8):80-82. 被引量:8
-
5李天然,陈自谦,赵春雷,钱根年,李铭山,许尚文.多层螺旋CT冠状动脉造影伪影及其产生因素的研究[J].医学影像学杂志,2007,17(9):980-984. 被引量:3
-
6Nakanishi T, Kayashima Y, Inoue R, et al. Pitfalls in 16 - detector row CT of the coronary arteries. Radiographics,2005 ;25 (2) :425 - 438.
-
7张敏,李石玲,郭智萍,张英华,王凤珍.64层螺旋CT冠状动脉血管成像技术[J].中国医学影像技术,2005,21(12):1948-1950. 被引量:24
二级参考文献19
-
1李新华,李强,张海宁,崔文国,李荣环,张振.医用CT的质量控制和保证[J].医疗卫生装备,2004,25(7):39-39. 被引量:16
-
2刘素峰.CT影像质量的保证和控制[J].医疗设备信息,2007,22(2):87-88. 被引量:13
-
3Ghersin E, Litmanovich D, Ofer A, et al. Anomalous origin of right coronary artery: diagnosis and dynamic evaluation with multidetector computed tomography [J]. J Comput Assist Tomogr,2004,28(2): 293-294.
-
4Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography[J]. Circulation, 2002, 106(16) :2051-2054.
-
5Ropers D, Baum U, Pohle K, et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J]. Circulation, 2003, 107(5) :664-666.
-
6Vogl TJ, Abolmaali ND, Diebold T, et al. Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography[J]. Radiology, 2002,223(1): 212-220.
-
7Sanz J, Rius T, Kuschnir P, et al. The importance of end-systole for optimal reconstruction protocol of coronary angiography with 16-slice multidetector computed tomography [J]. Invest Radiol,2005,40(3): 155-163.
-
8Cademartiri F, Luccichenti G, Marano R, et al. Techniques for the optimisation of coronary artery opacification in non-invasive angiography with a 16-row multislice computed tomography [J].Radiol Med (Torino), 2004,107(1-2) :24-34.
-
9Hong C,Becker CR,Huber A,et al.ECG-gated reconstructed multi-detector row CT coronary angiography:effect of varying trigger delay on image quality[J].Radiology,2001,220:712-717.
-
10Becker CR,Knez A,Leber A,et al.Initial experiences with multi-slice detector spiral CT in diagnosis of arteriosclerosis of coronary vessels[J].Radiologe,2000,40:118-122.
共引文献32
-
1刘平平,乔卫卫,刘同宝.64排螺旋CT在冠心病中的诊断价值[J].山东大学学报(医学版),2009,47(1):88-90. 被引量:4
-
2张丽红,李勇,黄贤会,肖太星,常维平.心电图编辑在提高64排螺旋CT冠状动脉成像质量中的应用[J].医学影像学杂志,2011,21(5):671-674. 被引量:2
-
3刘斌,赵红,吴兴旺,张家文,余永强,廖静敏.64层螺旋CT冠状动脉成像图像质量的相关影响因素分析(心脏体模模拟实验)[J].中华放射学杂志,2006,40(9):980-983. 被引量:38
-
4刘素堂,徐凯,李东野,夏勇,李绍东,李江山,王志荣,张超群,张辉.螺旋CT评估冠状动脉狭窄与钙化的价值[J].中国组织工程研究与临床康复,2007,11(1):178-179.
-
5赵红,刘斌,吴兴旺,余永强,沈云,廖静敏.64层螺旋CT冠状动脉成像的心率变化及其对图像质量的影响[J].实用放射学杂志,2007,23(2):145-149. 被引量:48
-
6刘斌,赵红,吴兴旺,张家文,余永强,沈云,廖静敏.心率对64层螺旋CT冠状动脉成像图像质量的影响[J].放射学实践,2007,22(5):444-447. 被引量:41
-
7赵红,刘斌,程自平,余永强,沈云,廖静敏.64-SCTCA与CCA对钙化及非钙化性冠状动脉狭窄程度评估的一致性分析[J].中国医学影像技术,2008,24(2):231-234. 被引量:13
-
8李伟,蒋定尧.心率对双源CT冠状动脉CTA成像质量影响分析[J].实用放射学杂志,2008,24(11):1569-1571. 被引量:3
-
9孙新海,史志涛,陈月芹,张谷青,李慧,王玉红.双源CT在心律失常患者冠状动脉成像中的应用[J].中国中西医结合影像学杂志,2009,7(3):188-191. 被引量:4
-
10张玉松.64排螺旋CT冠状动脉成像的临床应用[J].中国实用医药,2009,4(27):45-46.
-
1丁元洪,张功礼,邹文远,刘玥.腰椎间盘突出症CT诊断的误诊漏诊原因分析[J].中国疗养医学,2001,10(5):75-76.
-
2顾庆春,范亦辉,张振岳,吕传国,毛健,黄永东,薛春华,郁冬梅,顾仲依.40层螺旋CT冠状动脉造影诊断冠状动脉狭窄[J].中国医学影像学杂志,2009,17(1):25-28. 被引量:5
-
3王良东,邢孟琴,张艳芹.64排螺旋CT冠状动脉成像诊断心肌桥价值[J].中华实用诊断与治疗杂志,2011,25(1):65-66. 被引量:12
-
4罗秀芬.CT增强扫描420例的观察与护理[J].中国误诊学杂志,2011,11(26):6508-6508. 被引量:1
-
5陈秀梅,杜国新,齐玲俊,古力米热.40层螺旋CT冠状动脉成像时心率对成像质量的影响[J].新疆医学,2010,39(6):13-17.
-
6崔铱婕.多层螺旋CT对于支气管动脉与肺动脉造影对肺癌血液供应的分析[J].临床肺科杂志,2014,19(1):184-185. 被引量:3
-
7姜红.128层螺旋CT冠状动脉成像在冠心病中的应用效果研究[J].中外女性健康研究,2015,0(14):222-222.
-
8方汉贞.高分辨率CT最大密度投影在肺弥漫性微小结节中的应用[J].中国医药指南,2014,12(10):71-72. 被引量:4
-
9王廷昱,陈奋,陈旭,陈晶,陈大和.三期螺旋CT扫描对肝转移瘤的诊断价值[J].医学影像学杂志,2004,14(10):818-820. 被引量:15
-
10蓝柳,杨春旭.放射性肺损伤的检测与防治进展[J].实用医学杂志,2011,27(17):3251-3252. 被引量:10