摘要 作为起爆器材的毫秒延期电雷管,其秒量精度的问题一直是爆破工程界关注的焦点问题,而毫秒延期电雷管的秒量精度主要取决于延期元件,通过对延期元件加工工艺及贮存过程中,秒量精度影响因素的分析和研究,找出了提高该延期元件秒量精度的工艺技术途径,为更好地生产该产品奠定基础。 As millisecond delay detonating devices electric detonators, the delay precision of the accuracy of the problem has been the focus of attention problems. While millisecond delay electric detonators of the delay accuracy depends on delay element. In this paper,through the delay element in the manufacturing and storing process delayed the accuracy of the influencing factor analysis and research, the technologycal measures of improving the delay element the delay precision are taken, to produce this product to lay the foundation well.