摘要
对日开夜停的燃气—蒸汽联合循环机组进行合理的保温保压,能加快余热锅炉升温升压速度、缩短机组加负荷的时间。介绍了S109FA机组在日开夜停中的保温保压目的及相关问题,对同类型机组具有较好的参考价值。
This article mainly discusses temperature and pressure maintenance problems of S109FA unit in day-running night-down shift. The conclusion will have good effects on increasing HRSG start-up speed and reducing the unit raise load time, and also offer a preferable reference to the same type unit.
出处
《浙江电力》
2009年第5期45-47,共3页
Zhejiang Electric Power
关键词
S109FA
保温
保压
S109FA unit
temperature maintenance
pressure maintenance