期刊文献+

高分辨针孔SPECT三维图像重建的实现 被引量:2

Implementation of High-Resolution Pinhole SPECT 3D Image Reconstruction
下载PDF
导出
摘要 采用一种新颖的查找表法来实施有序子集期望值最大化(OSEM)的针孔SPECT图像重建算法,有效地将针孔响应修正包含在查找表中,进而实现高分辨针孔SPECT的三维图像重建。标准Jaszczak模具的成像实验结果表明:该方法不但能显著减少图像重建过程的计算时间和内存占用,且能显著改善重建图像的分辨率。因此,查找表法是能够快速实现针孔SPECT OSEM图像重建算法,并能将针孔响应修正包含在查找表中以获取高分辨断层图像的有效方法。 In order to achieve high-resolution pinhole SPECT image reconstruction, a novel lookup table (LUT) method was implemented in the ordered subsets expectation maximization (OSEM) algorithm including an effective compensation of the pinhole response. A standard Jaszczak phantom was used to evaluate the reconstruction algorithm. The results show that the OSEM algorithm with the LUT method can significantly reduce the CPU time and the usage of memory, and provide significant improvement of the spatial resolution of the reconstructed image. In conclusion, the LUT method with pinhole response corrections in LUT is an effective approach to implement OSEM algorithm for high-resolution pinhole SPECT image reconstruction.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2009年第11期1034-1038,共5页 Atomic Energy Science and Technology
基金 国家自然科学基金资助项目(30570520) 上海市"浦江人才计划"资助项目
关键词 针孔SPECT图像重建 OSEM算法 针孔响应修正 pinhole SPECT image reconstruction OSEM algorithm pinhole response correction
  • 相关文献

参考文献7

  • 1SHEPP L A, VARDI Y. Maximum likelihood reconstruction for emission tomography[J]. IEEE Transactions on Medical Imaging, 1982, 1(2) : 113-122.
  • 2MILLER M I , SNYDER D L , MILLER T R.Maximum likelihood reconstruction for singlephoton emission computed tomography[J]. IEEE Transactions on Nuclear Science, 1985, 32(1): 769-778.
  • 3HUDSON M H, LARKIN R S. Accelerated image reconstruction using ordered subsets of projection data[J]. IEEE Transactions on Medical Imaging, 1994, 13(4): 601-609.
  • 4KAMPHUIS C, BEEKMAN F J, VIERGEVER M A. Evaluation of OS-EM vs. ML-EM for 1D, 2D and fully 3D SPECT reconstruction[J].IEEE Transactions on Nuclear Science, 1996, 43(3): 2 018-2 024.
  • 5BEEKMAN F J, HAVE F, VASTENHOUW B, et al. U-SPECT-I: A novel system for submi- llimeter resolution tomography with radiolabeled molecules in mice[J]. Journal of Nuclear Medicine, 2005, 46(7): 1 194-1 200.
  • 6HAVE F, VASTENHOUW B, RENTMEESTER M, et al. System calibration and statistical image reconstruction for ultra-high resolution stationary pinhole SPECT[J]. IEEE Transactions on Medical Imaging, 2008, 27(7): 960-971.
  • 7代秋声,漆玉金.高分辨micro-SPECT成像系统针孔准直器的优化设计[J].原子能科学技术,2008,42(6):535-539. 被引量:3

二级参考文献6

  • 1WEISSLEDER R, MAHMOOD U. Molecular imaging[J]. Radiology, 2001, 219: 316-333.
  • 2MEIKLE S R, KENCH P, KASSIOU M, et al. Small animal SPECT and its place in the matrix of molecular imaging technologies[J]. Physics in Medicine and Biology, 2005, 501 45-61.
  • 3WEBER D A, IVANOVIC M, FRANCESCHI D, et al. Pinhole SPECT: An approach to in vivo high resolution SPECT imaging in small laboratory animals [J]. Journal of Nuclear Medicine, 1994, 35: 342-348.
  • 4ANGER H O. Radioisotope cameras in instrumentation in nuclear medicine: Vol. 1 [M]. New York: Academic, 1967: 485-552.
  • 5van der HAVE F, FREEK J B. Photon penetration and scatter in micro-pinhole imaging: A Monte-Carlo investigation[J]. Physics in Medicine and Biology, 2004, 49: 1 369-1 386.
  • 6BRIESMEISTER J F. MCNP4B: A general MonteCarlo N particle transport code: Version 4B, LA-12625-M[R]. USA: Los Alamos National Laboratory, 1997.

共引文献2

同被引文献18

  • 1尤江生,包尚联,蔡建新,王卫东.SPECT准直器几何及图像重建算法的进展[J].核电子学与探测技术,1997,17(3):221-224. 被引量:1
  • 2吴建波,王建斌,李勇,等.NK细胞治疗晚期恶性肿瘤转移灶的临床观察[J].中国美容医学,2012,21(z1):72-74.
  • 3宫丽华,孙晓淇,刘宝岳,等.前列腺癌骨转移灶中BMP-2、BMP-4、BMP-7的表达及临床意义[J].临床与文验病理学杂志,2012.28(8):870-873.
  • 4GROCH M W,ERWIN W D. SPECT in the year 2000:Basic principles[J].Journal of Nuclear Medicine Technology,2000,(04):233-244.
  • 5YANG Y W,CHEN J C,CHANG C J. Evaluation of collimator choice and scatter correction on 123I SPECT images[J].Nuclear Instruments and Methods in Physics Research A:Accelerators,Spectrometers,Detectors and Associated Equipment,2008.204-211.
  • 6HRUSKA C B,O' CONNOR M K. Effect of collimator selection on tumor detection for dedicated nuclear breast imaging systems[J].IEEE Transactions on Nuclear Science,2006,(05):2680-2689.doi:10.1109/TNS.2006.879824.
  • 7CAO Z X,BAL G,ACCORSI R. Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging:A simulation study[J].Physics in Medicine and Biology,2005.4609-4624.
  • 8MAHMOOD S T,ERLANDSSON K,CULLUM I. Design of a novel slit-slat collimator system for SPECT imaging of the human brain[J].Physics in Medicine and Biology,2009.3433-3449.
  • 9VUNCKX K,BEQU D,DEFRISE M. Single and multipinhole collimator design evaluation method for small animal SPECT[J].IEEE Transactions on Medical Imaging,2008,(01):36-46.doi:10.1109/TMI.2007.902802.
  • 10MAHMOOD S T,ERLANDSSON K,CULLUM I. The potential for mixed multiplexed and non-multiplexed data to improve the reconstruction quality of a multi-slit-slat collimator SPECT system[J].Physics in Medicine and Biology,2010.2247-2268.

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部