期刊文献+

硅酸镥闪烁体γ高剂量率脉冲线性响应上限测量 被引量:2

Measurement of Linear Response Upper Limit for Lutecium Oxyorthosilicate Scitillator in High Dose Rate to Pulsed Gamma Radiation
下载PDF
导出
摘要 在"强光一号"高剂量率脉冲伽马装置上,使用李萨如图形法测量了硅酸镥闪烁体的γ高剂量率脉冲线性响应上限。实验结果表明:硅酸镥闪烁体在脉冲伽马能注量率小于1.9×1019MeV/(cm2.s)时,光输出为线性;大于此限值时,出现非线性响应现象。 The linear response upper limit of lutecium oxyorthosilicate scitillator at high dose rate to pulsed gamma radiation was measured by using Lissajous figure method at the pulsed gamma equipment 'Qiangguang-Ⅰ'. The results of experiment indicate that the light response of LSO is still linear when the pulsed gamma energy flux is below 1.9 × 10^19 MeV/(cm^2 · s), otherwise, non-linear phenomenon appears.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2009年第10期942-945,共4页 Atomic Energy Science and Technology
关键词 李萨如图形 硅酸镥闪烁体 剂量率 线性响应上限 Lissajous figure lutecium oxyorthosilicate scintillator dose rate linear response upper limit