期刊文献+

Diagnostic performance of magnetic resonance venography in the detection of recanalization in patients with chronic cerebral venous sinus thrombus 被引量:7

Diagnostic performance of magnetic resonance venography in the detection of recanalization in patients with chronic cerebral venous sinus thrombus
原文传递
导出
摘要 Background In the chronic stage of cerebral venous sinus thrombosis (CVST), recanalization can result in disparate MR appearances. We aimed to prospectively investigate the diagnostic accuracy of magnetic resonance venography (MRV) in the evaluation of the recanalization of CVST. Methods This study prospectively evaluated the diagnostic performance of 2-dimensional time-of-flight (2D-TOF) MRV in thirty-two consecutive patients during a threeto six-month follow-up for CVST. Both 2D-TOF MRV and digital substraction angiography (DSA) were undertaken. Diagnostic accuracy of 2D-TOF MRV in the detection of recanalized thrombus was evaluated using DSA as the reference standard. Results MRV and DSA were completed without complications in all 32 patients. The sensitivity, specificity, positive predictive value, and negative predictive value of 2D-TOF MRV for the detection of recanalization on a segmental basis were 91% (62/68), 93% (37/40), 95% (62/65), and 86% (37/43) respectively. Conclusion 2D-TOF MRV provides high sensitivity and specificity for the diagnosis of recanalized CVST segments. Background In the chronic stage of cerebral venous sinus thrombosis (CVST), recanalization can result in disparate MR appearances. We aimed to prospectively investigate the diagnostic accuracy of magnetic resonance venography (MRV) in the evaluation of the recanalization of CVST. Methods This study prospectively evaluated the diagnostic performance of 2-dimensional time-of-flight (2D-TOF) MRV in thirty-two consecutive patients during a threeto six-month follow-up for CVST. Both 2D-TOF MRV and digital substraction angiography (DSA) were undertaken. Diagnostic accuracy of 2D-TOF MRV in the detection of recanalized thrombus was evaluated using DSA as the reference standard. Results MRV and DSA were completed without complications in all 32 patients. The sensitivity, specificity, positive predictive value, and negative predictive value of 2D-TOF MRV for the detection of recanalization on a segmental basis were 91% (62/68), 93% (37/40), 95% (62/65), and 86% (37/43) respectively. Conclusion 2D-TOF MRV provides high sensitivity and specificity for the diagnosis of recanalized CVST segments.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2009年第20期2428-2432,共5页 中华医学杂志(英文版)
关键词 venous sinus thrombosis cranial magnetic resonance venography angiography digital subtraction venous sinus thrombosis, cranial magnetic resonance venography angiography, digital subtraction
  • 相关文献

参考文献17

  • 1Stare J.Cerebral venous and sinus thrombosis:incidence and causes.Adv Neurol 2003; 92:225-232.
  • 2Bousser MG,Chiras J,Bories J,Castaigne P.Cerebral venous thrombosis-a review of 38 cases.Stroke 1985; 16:199-213.
  • 3Mattle HP,Wentz KU,Edelman RR,Wallner B,Finn JP,Barnes P,et al.Cerebral venography with MR.Radiology 1991; 178:453-458.
  • 4Harper CM Jr,O'Neill BP,O'Duffy JD,Forbes GS.Intracranial hypertension in Behcet's disease:demonstration of sinus occlusion with use of digital subtraction angiography.Mayo Clin Proc 1985; 60:419-422.
  • 5White JB,Kaufmann TJ,Kallmes DF.Venous sinus thrombosis:a misdiagnosis using MR angiography.Neurocrit Cure 2008; 8:290-292.
  • 6Rollins N,Ison C,Reyes T,Chia J.Cerebral MR venography in children:comparison of 2D time-of-flight and gadolinium-enhanced 3D gradient-echo techniques.Radiology 2005; 235:1011-1017.
  • 7Kirchhof K,Welzel T,Jansen O,Sartor K.More reliable noninvasive visualization of the cerebral veins and dural sinuses:comparison of three MR angiographic techniques.Radiology 2002; 224:804-810.
  • 8Furb RI,Scott JN,Willinsky RA,Montanera Wl,Wright GA,terBrugge KG.Intracranial venous system:gadolinium-enhanced three-dimensional MR venography with auto-triggered elliptic centric-ordered sequence-initial experience.Radiology 2003; 226:203-209.
  • 9Dormont D,Anxionnat R,Evrard S,Louaille C,Chiras J,Marsault C.MRI in cerebral venous thrombosis.J Neuroradiol 1994; 21:81-99.
  • 10Rippe DJ,Boyko OB,Spritzer CE,Meisler WJ,Dumoulin CL,Souza SP,et al.Demonstration of dural sinus occlusion by the use of MR angiography.AJNR Am J Neuroradiol 1990; 11:199-201.

同被引文献41

引证文献7

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部