Dose Distribution Verifications of IMRT for NPC 被引量:1

Dose Distribution Verifications of IMRT for NPC
下载PDF
导出
摘要 In order to explore a dose distribution verification procedure of intensity modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) and establish its evaluation criteria, we performed 35 two-dimensional (2D) patient-specific IMRT verifications over the year i006. The percent of pixels passing 7 and the normalized agreement test (NAT) index were mainly used to represent the agreement between the measured and computed dose distributions with three criteria (2%/2 mm, 3%/3 mm and 5%/3 mm) as recommended in the literature. The results were that all cases passed through verifications with three criteria except that the NAT index of one case was beyond the limitation, and the three tolerance levels of 2%/2mm, 3%/3 mm and 5%/3 mm produced similar clinical verification results but led to different percent of pixels passing Y and NAT index. Our data showed that the percent of pixels passing y and the NAT index were complementary to evaluate future IMRT verifications as two significant metrics. Due to the influence of the noise and the trait of the software, we considered an IMRT plan as acceptable in case of the percent ofpixels passing y 〉95% and the NAT index 〈5 with the 5%/3 mm criteria for IMRT patient-specific quality assurance (QA). In order to explore a dose distribution verification procedure of intensity modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) and establish its evaluation criteria, we performed 35 two-dimensional (2D) patient-specific IMRT verifications over the year i006. The percent of pixels passing 7 and the normalized agreement test (NAT) index were mainly used to represent the agreement between the measured and computed dose distributions with three criteria (2%/2 mm, 3%/3 mm and 5%/3 mm) as recommended in the literature. The results were that all cases passed through verifications with three criteria except that the NAT index of one case was beyond the limitation, and the three tolerance levels of 2%/2mm, 3%/3 mm and 5%/3 mm produced similar clinical verification results but led to different percent of pixels passing Y and NAT index. Our data showed that the percent of pixels passing y and the NAT index were complementary to evaluate future IMRT verifications as two significant metrics. Due to the influence of the noise and the trait of the software, we considered an IMRT plan as acceptable in case of the percent ofpixels passing y 〉95% and the NAT index 〈5 with the 5%/3 mm criteria for IMRT patient-specific quality assurance (QA).
机构地区 Cancer Center
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第5期673-676,共4页 华中科技大学学报(医学英德文版)
关键词 dose distribution dose verification intensity modulated radiation therapy dose distribution dose verification intensity modulated radiation therapy
  • 相关文献

参考文献2

二级参考文献1

  • 1胡逸民,肿瘤放射物理学,1999年,613页

共引文献106

同被引文献7

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部