摘要
建立了火焰原子吸收光谱法测定消朦胶囊中锌含量的方法。用盐酸溶解样品,以火焰原子吸收法测定锌,结果显示,该方法线性关系良好(r=0.9991),检出限为0.01μg/mL,回收率97.0%—103.5%。与药典测试方法相比,本方法操作简单,重现性好。
The sample was dissolved by hydrochloric acid(1:1).The content of zinc in xiaomeng capsule was determined by FAAS.The detection limit is 0.01μg/mL(r=0.9991).The method is easy to operate with highly reproducibility.
出处
《光谱实验室》
CAS
CSCD
北大核心
2009年第5期1126-1128,共3页
Chinese Journal of Spectroscopy Laboratory
关键词
锌
火焰原子吸收光谱法
消朦胶囊
Zinc
Flame Atomic Absorption Spectrometry
Xiaomeng Capsule