摘要 根据光纤光导的耦合理论,推导了闪烁体-光纤组合式探测器γ灵敏度理论公式,计算了LSO、ST401两种闪烁体-光纤探测器的相对灵敏度,在平均能量为1.25MeV的60Co射线源上测得10mm厚LSO闪烁体-光纤组合式探测器的灵敏度是相同厚度ST401的19倍,理论计算和实验结果在不确定度范围内一致。 This work is aimed at developing the technique of multi-channel scintillator-fiber detector. In this paper, theoretical gamma sensitivity of a fiber detector was formulated for calculating the relative sensitivity of LSO and ST401 scintillator-fiber detectors. Outcomes of the calculation were validated by experiment with a ^60Co source. The results show that sensitivity of an LSO scintillator-fiber detector of 10-mm thicknesd is about 19 times higher than the system using ST401 with the same size of LSO detector. The theoretical results agree with the experimental data.
出处 《核技术》 CAS CSCD 北大核心 2009年第11期867-871,共5页 Nuclear Techniques
关键词 闪烁体-光纤辐射探测器 Γ灵敏度 耦合效率 Scintillator-fiber detector, Gamma sensitivity, Coupling efficiency
  • 相关文献

参考文献11

  • 1Lyons P B, Golob J E. Fiber optic utillization at the Nevada test, LA-7029.
  • 2Lyons P B, Ogle J W, Nelson M A. Applications of optical fibers in nuclear diagnostics, LA-UR-80-1107.
  • 3黄裕年,刘雅君.辐射诊断用的光纤传输系统[J].应用光学,1999,20(2):24-27. 被引量:1
  • 4Shikama T, Toh K, Nagata S, et al. Nucl Fusion, 2006, 46: 46-50.
  • 5Bondarenko A V, Dyad'kin A P. Instrum Exp Tech, 2006, 49(2): 187-189.
  • 6吕敏,王奎禄.核试验脉冲射线测量技术.北京:国防工业出版社,2006.
  • 7Snyder A W,Mitchell D J,著.光波导理论.周幼威,张一龙,等译.北京:人民邮电出版社,1991.602-623.
  • 8刘福华,冯国斌,宋文卿.耐辐照光纤瞬态辐照参数测量[归档报告].西北核技术研究所,1993.
  • 9谢红卫 宋顾周 李宏云.试验与研究,2003,26(1):92-96.
  • 10PTW Corporation. UNIDOS10002 User's manual. Lorracher Str.7, Germany.