摘要
根据多年的施工经验和现场调查,并结合预应力管桩规范,对静压桩爆桩的原因进行了分析,提出了静压桩施工中应注意的问题和预防控制措施,从而确保静压桩工程的顺利进行。
According to many-year construction experience and scene investigation and combining with the regulation for prestressed pipe pile,the paper analyzes reasons for the explosion in static piles,advancing the problem should be attention and preventive controlling measures,so as to ensure the smooth operation of the static pile engineering.
出处
《山西建筑》
2009年第33期138-139,共2页
Shanxi Architecture
关键词
静压桩
爆桩
预防控制措施
static pile
explosion in piles
preventive controlling measures