期刊文献+

合肥市居住建筑的能耗分析 被引量:1

The energy consumption analysis of residential building in Hefei city
下载PDF
导出
摘要 依据《合肥市居住建筑节能设计标准实施细则》规定的经济保温层厚度,采用DeST-h动态负荷分析软件,计算合肥市某住宅建筑外墙的不同保温层厚度对建筑能耗的影响,得出具体建筑的最佳保温层厚度,同时,分析了不同通风模式下房间的基础室温和建筑能耗,得出该地区在空调季不同月份的最佳通风方案。 Based on the economic insulating layer depth regulated by the Detailed Regulations for Energy Conservation Design Standard far Residential Building of Hefei, the effect of different insulating layer depth of building external wall of some housing in Hefei city on building energy consumption was calculated using DeST-h dynamic load analysis software, and the optimized insulating layer depth to concrete building was got. Meanwhile, the base room temperature and building energy consumption of room at different ventilation mode were analyzed, and the optimized ventilation scheme at different months of air-conditioning season in this area was got.
作者 张抗 沈致和
机构地区 合肥工业大学
出处 《山西建筑》 2009年第33期239-241,共3页 Shanxi Architecture
关键词 DeST 居住建筑 能耗分析 通风模式 DeST residential building energy consumption analysis ventilation mode