期刊文献+

Assessment of Coronary Stents by 64-slice Computed Tomography: In-stent Lumen Visibility and Patency 被引量:4

Assessment of Coronary Stents by 64-slice Computed Tomography: In-stent Lumen Visibility and Patency
下载PDF
导出
摘要 Objective To assess lumen visibility of coronary stents by 64-slice computed tomography (CT) coronary angiography, and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coronary artery stent implantation. Methods Totally, 60 patients (54 males, aged 57.0±12.7 years) and /05 stents were investigated by 64-slice CT at a mean interval of 20.0±16.6 months after coronary stents implantation. Axial multi-planar reconstruction images of the stents and curved-planar reconstruction images through the median of the stents were reconstructed for evaluating stent image quality on a 5-point scale (1=excellent, 5=nonassessable), and stent lumen diameter was detected. Conventional coronary angiography was performed in 18 patients, and 32 stents were evaluated. Results Image quality was good to excellent on average (score 1.71±0.76). Stent image quality score was correlated to heart rate (r=0. 281, P〈0.01) and stent diameter (r=-0.480, P〈0.001). All the stents were assessable in lumen visibility with an average visible lumen diameter percentage of 60.7%±13.6%. Visible lumen diameter percentage was correlated to heart rate (r=-0.193, P〈0.05), stent diameter (r=0.403, P〈0.001), and stent image quality score (r=-0.500, P〈0.001). Visible lumen diameter percentage also varied depending on the stent type. In comparison with the conventional coronary angiography, 4 of 6 in-stent stenoses were correctly detected. The sensitivity and specificity for the detection of in-stent stenosis were 66.7% and 84.6%, respectively. Conclusions Using a 64-slice CT, the stent lumen is partly visible in most of the stents. And 64-slice CT may be useful in the assessment of stent patency.
出处 《Chinese Medical Sciences Journal》 CAS CSCD 2009年第3期156-160,共5页 中国医学科学杂志(英文版)
关键词 coronary artery in-stent restenosis computed tomography 冠状动脉支架 计算机断层扫描 可见性 流明 评估
  • 相关文献

参考文献11

  • 1F. Cademartiri,A. Palumbo,E. Maffei,L. Grutta,G. Runza,F. Pugliese,M. Midiri,N. R. A. Mollet,W. B. Meijboom,A. Menozzi,L. Vignali,C. Reverberi,D. Ardissino,G. P. Krestin.Diagnostic accuracy of 64-slice CT in the assessment of coronary stents[J].La radiologia medica.2007(4)
  • 2David Maintz,Harald Seifarth,Rainer Raupach,Thomas Flohr,Michael Rink,Torsten Sommer,Murat ?zgün,Walter Heindel,Roman Fischbach.64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents[J].European Radiology.2006(4)
  • 3Oncel D,Oncel G,Karaca M.Coronary stent patency and in-stent restenosis: determination with 64-section mul- tidetector CT coronary angiography-initial experience[].Radiology.2007
  • 4Mollet NR,Cademartiri F,van Mieghem CA,et al.High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography[].Circulation.2005
  • 5Kruger S,Mahnken A H,Sinha A M,et al.Multislice spiral computed tomography for the detection of coronary stent restenosis and patency[].International Journal of Cardiology.2003
  • 6Narins CR,Holmes DR,Topol EJ.A call for provisional stenting:the balloon is back![].Circulation.1998
  • 7Maintz,D,Seifarth,H,Raupach,R.64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents[].European Radiology.2005
  • 8JD Schuijf,JJ Bax,JW Jukema.Feasibility of assessment of coronary stent patency using 16-slice computed tomography[].The American Journal of Cardiology.2004
  • 9Kitagawa,T.,Fujii,T.,Tomohiro,Y.Noninvasive assessment of coronary stents in patients by 16-slice computed tomography[].International Journal of Cardiology.2006
  • 10Maintz,D.,Grude,M.,Fallenberg,E.M.Assessment of coronary arterial stents by multislice-CT angiography[].Acta Radiologica.2003

同被引文献4

引证文献4

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部