期刊文献+

Pupil constriction can alter the accuracy of dark room provocative test 被引量:4

Pupil constriction can alter the accuracy of dark room provocative test
原文传递
导出
摘要 Background Primary angle-closure glaucoma (PACG) is a major cause of visual morbidity in East Asia. Dark-room provocative test (DRPT) has been used to determine which narrow angles have the risk to develop angle closure. However, the accuracy of DRPT might be altered because that after emerging from the dark room, the configuration of the angle is affected by the light of the slit-lamp and the appositionally closed angle reopens. The aim of this study was to examine the pupillary diameter in different light conditions and use it as a parameter to assess the accuracy of dark-room provocative test. Methods Patients with suspected primary angle-closure glaucoma undergoing DRPT were recruited. The anterior chamber angle was examined by anterior segment optical coherence tomography under the following conditions: (1) in standard room illumination; (2) after short-term dark-adaptation and (3) after DRPT. Mean values of pupil size and numbers of appositionally closed angle under different conditions were compared. Results A total of 47 eyes of 47 patients were analyzed. The pupil size after DRPT was smaller than that after short-term dark-adaptation (P 〈0.001) and smaller than that in standard room illumination (P=0.026). The numbers of appositionally closed angles after short-term dark-adaptation were significantly larger than those after DRPT (P 〈0.001). There was no significant difference between the numbers of appositionally closed angles in standard room illumination and after DRPT (P=-0.157). Conclusions Constriction of pupil size immediately after prolonged dark room provocative test may lead to change in the angle configuration, which may lead to false negative results. We suggest a modified protocol of recording intraocular pressure immediately after DRPT and performing gonioscopy following short-term dark adaptation to improve the accuracy of angle closure assessment. Background Primary angle-closure glaucoma (PACG) is a major cause of visual morbidity in East Asia. Dark-room provocative test (DRPT) has been used to determine which narrow angles have the risk to develop angle closure. However, the accuracy of DRPT might be altered because that after emerging from the dark room, the configuration of the angle is affected by the light of the slit-lamp and the appositionally closed angle reopens. The aim of this study was to examine the pupillary diameter in different light conditions and use it as a parameter to assess the accuracy of dark-room provocative test. Methods Patients with suspected primary angle-closure glaucoma undergoing DRPT were recruited. The anterior chamber angle was examined by anterior segment optical coherence tomography under the following conditions: (1) in standard room illumination; (2) after short-term dark-adaptation and (3) after DRPT. Mean values of pupil size and numbers of appositionally closed angle under different conditions were compared. Results A total of 47 eyes of 47 patients were analyzed. The pupil size after DRPT was smaller than that after short-term dark-adaptation (P 〈0.001) and smaller than that in standard room illumination (P=0.026). The numbers of appositionally closed angles after short-term dark-adaptation were significantly larger than those after DRPT (P 〈0.001). There was no significant difference between the numbers of appositionally closed angles in standard room illumination and after DRPT (P=-0.157). Conclusions Constriction of pupil size immediately after prolonged dark room provocative test may lead to change in the angle configuration, which may lead to false negative results. We suggest a modified protocol of recording intraocular pressure immediately after DRPT and performing gonioscopy following short-term dark adaptation to improve the accuracy of angle closure assessment.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2009年第21期2620-2623,共4页 中华医学杂志(英文版)
关键词 angle closure glaucoma diagnostic test BIOMETRY angle closure glaucoma diagnostic test biometry
  • 相关文献

参考文献4

二级参考文献16

共引文献210

同被引文献33

  • 1李海燕,孙同,李莹,金玉梅,胡明,孙传宾.不同品牌准分子激光机对角膜切削深度的比较[J].中外医疗,2007(18):43-44. 被引量:10
  • 2徐亮.青光眼防治指南概要草案[J].眼科,2006,15(2):73-75. 被引量:9
  • 3Matthew E. Emanuel,Richard K. Parrish,Steven J. Gedde.Evidence-based management of primary angle closure glaucoma[J]. Current Opinion in Ophthalmology . 2014 (2)
  • 4Jacky Lee,Yuen,Yick,Lai.Argon laser peripheral iridoplasty versus systemic intraocular pressure-lowering medications as immediate management for acute phacomorphic angle closure[J]. Clinical Ophthalmology . 2013 (default)
  • 5Yuzhen Jiang,Dolly S. Chang,Paul J. Foster,Mingguang He,Shengsong Huang,Tin Aung,David S. Friedman.Immediate Changes in Intraocular Pressure after Laser Peripheral Iridotomy in Primary Angle-Closure Suspects[J]. Ophthalmology . 2012 (2)
  • 6David S Friedman,Paul J Foster,Tin Aung,Mingguang He.Angle closure and angle‐closure glaucoma: what we are doing now and what we will be doing in the future[J]. Clinical & Experimental Ophthalmology . 2012 (4)
  • 7Weng T Ng,William Morgan.Mechanisms and treatment of primary angle closure: a review[J]. Clinical & Experimental Ophthalmology . 2011 (4)
  • 8Monisha E Nongpiur,Judy YF Ku,Tin Aung.Angle closure glaucoma: a mechanistic review[J]. Current Opinion in Ophthalmology . 2011 (2)
  • 9Harry A. Quigley.The Iris Is a Sponge: A Cause of Angle Closure[J]. Ophthalmology . 2010 (1)
  • 10Bingsong Wang,Nathan G. Congdon,Ningli Wang,Kun Lei,Lan Wang,Tin Aung.Dark Room Provocative Test and Extent of Angle Closure: An Anterior Segment OCT Study[J]. Journal of Glaucoma . 2010 (3)

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部