期刊文献+

螺旋CT低剂量扫描在育龄男女骨盆病变中的应用研究 被引量:12

Clinical application of low-dose spiral CT screening in pelvis diseases of male/femal at child-bearing age
下载PDF
导出
摘要 目的:探讨育龄男女骨盆在做低剂量扫描时合理剂量选择及其应用价值。方法:选择96例患者,每个研究对象均用常规剂量(210mA)扫描,在征得患者同意后,用低剂量(50mA,25mA)再加扫一层或几层,两种扫描模式除了后者用低剂量技术,前者不用外,其余扫描参数相同,比较权重CT剂量学指数及CT图像质量的差别。结果:25mA时CTDIvol最小,为常规剂量扫描的11%,但图像质量与常规剂量相比差异有高度显著性(P<0.01);50mA时,CTDIvol为常规剂量扫描的22%,图像质量与常规剂量相比差异无显著性(P>0.05)。结论:育龄男女骨盆低剂量(50mA)扫描既可保证骨盆部病变的影像质量,又可降低患者的辐射剂量。 Objective:To explore the value of low-dose CT screening and the reasonable dose in the pelvis diseases of male/female at child-bearing age.Methods:96 patients were recruited in this study.Each patient was scanned in routine dose(210 mA) and,additionally,the low dose(50 mA,25 mA) scan was performed under the permission of the patients.Except the tube current(mA),the other scan parameters were all the same.The differences of CTDI vol(CT dose index) and image quality in different dose were compared.Results:Compared to routine scanning,CTDI vol of 25 mA was 11%,but the differences of the image quality was statistically significant(P〈0.01);While,CTDI vol of 50mA was 22%,but the difference of the image quality had no statistical significance(P〉0.05).Conclusion:Low dose CT scanning(50 mA) can decrease the radiation dose and,also,assure the image quality.
出处 《医学影像学杂志》 2009年第10期1315-1318,共4页 Journal of Medical Imaging
基金 山东省聊城市科技局科研立项课题(20060635218) 科研成果鉴定课题(2007086)
关键词 骨盆疾病 螺旋CT 低剂量 育龄 Pelvis disease Spiral CT Low dose Child-bearing age
  • 相关文献

参考文献3

二级参考文献22

  • 1刘昌盛,魏文洲,郑晓华,童世平,殷响林,杨洪飙.低剂量CT扫描对婴幼儿颅脑病变检查的防护价值[J].中华放射医学与防护杂志,2004,24(3):270-271. 被引量:67
  • 2赵修义,李国英,陈静,肖红,刘汝勤.CT检查的防护探讨[J].中华放射医学与防护杂志,1995,15(1):57-57. 被引量:10
  • 3Naidich D, Marshall C, Gribbin C, et al. Low - dose CT of the lungs: preliminary observations. Radiology, 1990; 175 (3): 729~731.
  • 4Prasad SR, Wittram C, Shepard JA, et al. Standard - dose and 50 % - reduced - dose chest CT: comparing the effect on image quality. AJR, 2002; 179(2) :461~465.
  • 5Brener DJ, Elliston CD, Hall EJ, et al. Estimated risks of radiation- induced fatal cancer from pediatric CT. AJR, 2001;176: 289~ 296.
  • 6Rusinek H, Naidich D, Mc Guinness G, et al. Pulmonary nodule detection: low dose versus conventional CT. Radiology,1998;209(1) :243~249.
  • 7Ambrosino MM, Genieser NB, Roche KJ, et al. Feasibility of high-resolution, low-dose chest CT in evaluation the pediatric chest. Pediatr Radiol, 1994; 24: 6~10.
  • 8Jayier L, Joaquim P, Pilar G, et al. Low- dose high- resolution CT of the chest in children and young adults: dose cooperation, artifact incidence, and image quality. AJR, 2000; 175:985~ 992.
  • 9Rogolla P, Stover B, Scheer I, et al. Low- dose spiral CT:applicability to paediatric chest imaging. Pediatr Radiol,1999;29(8) :565~569.
  • 10Polacin A, Kalender WA, Marchal G. Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology,1992; 185(1) :29~35.

共引文献57