期刊文献+

Biomechanical evaluation of lumbosacral reconstruction after subtotal sacrectomy: A three-dimensional finite element analysis

骶骨次全切除术后腰骶部重建的生物力学研究:三维有限元分析(英文)
下载PDF
导出
摘要 Objective: The aim of this study was to investigate the biomechanical property of lumbosacral reconstruction after subtotal sacrectomy. Methods: Three three-dimensional finite element models of lumbosacral region were established: (1) An intact model (INT); (2) A defective model (DEF) on which subtotal sacrectomy was performed cephalad to the $1 foramina; (3) A reconstructed model (REC). These models were validated by compared with literature. Upright posture was stimulated under a compression load of 925N. A finite element analysis was performed to account for the displacement and stress on the models. The REC model was calculated twice, with the material property of reconstruction instrument set as titanium and stainless steel, respectively. Results: The displacements of anchor point on the L3 vertebrae in INT, DEF and REC model were 6.63 mm, 10.62 mm, 4.29 mm (titanium) and 3.86 mm (stainless steel), respectively. The stress distribution of the instrument in REC model showed excessively concentration on caudal spinal rod, which may cause rod failure between spine and ilia. The maximum von Mise stress of stainless steel instrument was higher than that of titanium instruments (992 MPa vs 655 MPa), and the value of stress of anchor point around sacroiliac joint in REC model were 26.4 MPa with titanium instruments and 23.9 MPa with stainless steel instruments. Conclusion: Lumbosacral reconstruction can significantly increase the stiffness of spino-pelvis of the patient who underwent subtotal sacrectomy. However, the rod between L5 and ilia is the weakest region of all the instruments. It is suggested that the bending of rod should be conducted carefully and smoothly to avoid significant stress concentration so as to reduce the risk of rod failure. And stainless steel instrument has higher maximum stress and significantly greater stress shielding effect than titanium instrument, which means stainless steel instruments are of higher risk of rod failure and less favorable for lumboiliac arthrodesis than titanium instruments.
出处 《The Chinese-German Journal of Clinical Oncology》 CAS 2009年第11期638-641,共4页 中德临床肿瘤学杂志(英文版)
关键词 subtotal sacrectomy RECONSTRUCTION BIOMECHANICS finite element analysis 腰骶 生物力学 有限元分析 应力
  • 相关文献

参考文献10

  • 1Kawahara N, Murakami H, Yoshida A, et al. Reconstruction after total sacrectomy using a new instrumentation technique. Spine, 2003, 28: 1567-1572.
  • 2Polikeit A, Ferguson S J, Nolte LP, et al. Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis. Eur Spine J, 2002, 12: 413-420.
  • 3Hugate RR Jr, Dickey ID, Phimolsamti R, et al. Mechanical effects of partial sacrectomy: when is reconstruction necessary? Clin Orthop Relat Res, 2006, 450: 82-88.
  • 4Sato K, Kikuchi S, Yonezawa T. In vivo intradiscal pressure measurement in healthy individuals and in patients with ongoing back problems. Spine, 1999, 24: 2468-2474.
  • 5Gokaslan ZL, Romsdahl MM, Kroll SS, et al. Total sacrectomy and Galveston L-rod reconstruction for malignant neoplasms. J Neurosurg, 1997, 87: 781-787.
  • 6Wang ST, Goel VK, Fu CY, et al. Posterior instrumentation reduces differences in spine stability as a result of different cage orientations: an in vitro study. Spine, 2005, 30: 62-67.
  • 7Yamamoto I, PanjabiMM, Crisco T, et al. Three-dimensional movement of the whole spine and lumbosacral joint. Spine, 1989, 14: 1256-1260.
  • 8Localio SA, Eng K, Ranson JH. Abdominosacral approach for retrorectal tumors. Ann Surg, 1980, 191: 555-560.
  • 9Gennari L, Azzarelli A, Quagliuolo V. A posterior approach for the excision of sacral chordoma. J Bone Joint Surg Br, 1987, 69: 565-568.
  • 10Gunterberg B, Romanus B, Stener B. Pelvic strength after major amputation of the sacrum. An exerimental study. Acta Orthop Scand, 1976.47: 635-642.