介绍了安康水电站表孔消力池底板存在的主要缺陷,分析了破坏原因、历次补强加固处理方法及效果,并提出了从根本上解决表孔消力池安全隐患的建议。
This paper introduced the main defects of basin plate of stilling pool at Ankang hydropower station, and analysed the damage reason. Combined with former reinforcement, some suggestions on defect elimination were advanced.