期刊文献+

ICP-AES法测定钛钽铌合金中Ta、Nb元素 被引量:2

Determination of Nb, Ta in TiTaNb Alloy by ICP-AES
下载PDF
导出
摘要 研究了用高分辨率全谱直读等离子体发射光谱仪(ICP-AES)进行钛钽铌合金中钽、铌元素的测定。通过对试样溶样方法的选择,最终采用盐酸+氢氟酸溶解样品;对样品溶解酸度、元素分析谱线选择、背景校正扣除、样品基体及待测元素间干扰等因素进行了分析。采用基体匹配与背景扣除法消除钛基体对待测元素的光谱干扰,选择了最佳实验条件。结果表明:各元素的加标回收率为98.0%~104.0%,相对标准偏差小于2.0%。本法测定已用于钛钽铌产品的检验。 A new method was employed for the determination of Ta and Nb in Ti-Ta-Nb alloys by inductively coupled plasma atomic emission spetrometry(ICP-AES). The samples was dissolved in a mixture of hydrochloric, hydrofluoric and nitric acid. The effects of acid concentration, choice of analytical spectral lines for elements, background corrections, interferences from matrix and among elements determined were investigated. The optimal detection conditions were determined. The spectral interferences of matrix element titanium with the spectral lines of elements determined were corrected by the matrix matching and background correction methods. The recoveries for the elements were in the range of 98.0%~104.0 % and relative standard deviations were below 2.0%. The analytical method has been applied to product analysis.
出处 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2008年第A04期661-663,共3页 Rare Metal Materials and Engineering
关键词 ICP-AES 钛钽铌合金 inductively coupled plasma-atomic emission spectrometry Ti-Ta-Nb alloy tantalum niobium
  • 相关文献

参考文献4

  • 1Editorial Board of Analysizing Series for Nonferrous Metals Industry(有色金属工业分析丛书编委会).Metallurgic Analysis of Refractory and Rare Metals(难熔金属和稀散金属冶金分析)[M].Beijing:Metallurgic Press,1992.
  • 2Thompson M, Walsh J N. Translated by Fu Bin(符斌), Yin Xinping(殷欣平).Guide of Spectrum Analysis(光谱分析指南)[M].Beijing:Metallurgic Press,1991:31.
  • 3战国利.ICP-AES法测定钛合金中的6种元素[J].光谱实验室,2000,17(4):414-415. 被引量:10
  • 4郭剑虹,刘少清.用ICP-AES法测定钛合金中多元素[J].宝钢技术,2001(2):37-39. 被引量:11

二级参考文献2

  • 1有色金属工业产品化学分析方法标准汇编.2,1992年,427页
  • 2万家亮(译),电感耦合等离子体光谱分析,1989年

共引文献15

同被引文献2

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部