期刊文献+

复合絮凝剂在四氧化三锰工业污水处理中的应用 被引量:1

Application of Composite Flocculant to Industrial Wastewater Treatment of Mn_3O_4
下载PDF
导出
摘要 研究了用聚合氯化铝和聚丙烯酰胺复合絮凝剂处理四氧化三锰工业污水,考察了絮凝剂PAC加入量、助凝剂PAM加入量和加入时间对四氧化三锰工业污水絮凝效果的影响。试验结果表明:实验室过程中,在PAC加入量5mg/L,PAM加入量0.6mg/L,PAM在PAC加入后30s加入条件下,复合絮凝剂的絮凝效果最好,浊度去除率可达94.8%,达到了工业污水排放的国家标准。还对复合絮凝剂在工业污水处理应用中应注意的问题进行了简要分析。 The paper studies the Mn3O4 wastewater treatment with the composite flocculant of Polyaluminium Chloride and investigates the flocculating effects by adding the amount of PAC and PAM and the time required. The experiment results showed that the flocculating effects can be optimum when adding 5 mg/L of PAC, 0.6 mg/L of PAM for 30 min. The turbidity removal rate reached 94.8% , which has been satisfied with the State Standard for Industrial Sewage Discharge. This paper also briefly analyzes some problems in application of composite flocculant to industrial wastewater treatment of Mn3O4.
出处 《金属矿山》 CAS 北大核心 2009年第11期136-138,共3页 Metal Mine
关键词 复合絮凝剂 四氧化三锰 工业污水 Composite flocculant,Mn3O4 ,Industrial wastewater
  • 相关文献

参考文献4

二级参考文献26

  • 1王静超,马军,韩宏大.探讨气浮工艺的若干技术参数[J].中国给水排水,2004,20(6):22-24. 被引量:20
  • 2刘海龙,王东升,汤鸿霄.典型南方源水的有机高分子助凝研究[J].中国给水排水,2005,21(7):1-4. 被引量:6
  • 3曾克新.我国四氧化三锰生产现状及发展预测[J].中国锰业,2006,24(1):6-8. 被引量:5
  • 4LUANZhaokun(栾兆坤) YUZhendong(宇振东).Flocculating mechanism of Inorganic polymer flocculant and its application .环境污染治理技术与设备,1981,2(3):46-51.
  • 5COLLINS G L, JAMESON G J. Double-layer effects in the flotation of fine particles[J]. Chem Eng Sci, 1977, 32(3): 239- 246.
  • 6Gregory J, Dupont V, Properties of Flocs Produced by Water Treatment Coagulants. Water Science and Technology, 2001,44 (10) :231 -236
  • 7Jung S J, Amal R, Raper J A, Monitoring Effects of Shearing on Floc Structure Using Small-Angle Light Scattering. Powder Technology,1996, 88:51-54
  • 8Bache D H, Rasool E, Moffat D et al. , On the Strength and Character of Alumino-Humic Flocs. Water Science and Technology, 1999,40:81-88
  • 9Sharna M Glover, Yan Yao-de, Graeme Jameson Jet al. , Bridging Flocculation Studied by Light Scattering and Settling. Chemical Engineering, 2000, 80:3-12
  • 10Wu R M, Tsou G W, Lee D J, Estimation of the Interior Permeability of Polymer-Flocculated Sludge Flocs. Environmental Research,2004, 4:163-167

共引文献29