采用程序化操作可以降低变电站值班员的工作压力与劳动强度,并减少误操作的概率。以苏州500kV木渎变电站实现程序化操作为例,介绍了在500 kV监控中心执行程序化操作的实现方法、操作对象及设备状态判据,并通过实际运行效果证明了程序化操作的高效性和准确性,值得广泛推广。
The programmed operation can not only alleviate the work pressure and labor intensity for the operator on duty in substations but also reduce maloperation.Taking the 500 kV Mudu Substation in Suzhou as an example,the realization of the programmed operation in the 500 kV supervisory control center was presented,as well as related operating object and equipment condition assessment criteria.Practice proved the programmed operation effective and accurate.
出处
《华东电力》
北大核心
2009年第10期1761-1763,共3页
East China Electric Power