期刊文献+

Analysis of saturation signal correction of the troposphere lidar 被引量:6

Analysis of saturation signal correction of the troposphere lidar
原文传递
导出
摘要 Usually, lidar detection systems are optimized for the measurement of the low intensity signal using the photon counting technique, but this approach results in the nonlinear signal response for the higher intensity signal. The problem is successfully solved by the combination of analog-to-digital (AD) and photon- counting (PC) detection. The optimized processing procedure of the signal combination of AD and PC is described, and the corrected result is analyzed and compared with the results by the dealt-time correction method. In this way, the accuracy of wind and aerosol measurement in the nonlinear range is improved. In addition, the signal-to-noise ratios (SNRs) of the two detection methods of AD and PC are compared in the overall dynamic range of signal for the performance analysis. Usually, lidar detection systems are optimized for the measurement of the low intensity signal using the photon counting technique, but this approach results in the nonlinear signal response for the higher intensity signal. The problem is successfully solved by the combination of analog-to-digital (AD) and photon- counting (PC) detection. The optimized processing procedure of the signal combination of AD and PC is described, and the corrected result is analyzed and compared with the results by the dealt-time correction method. In this way, the accuracy of wind and aerosol measurement in the nonlinear range is improved. In addition, the signal-to-noise ratios (SNRs) of the two detection methods of AD and PC are compared in the overall dynamic range of signal for the performance analysis.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2009年第11期1051-1054,共4页 中国光学快报(英文版)
基金 supported bythe National Natural Science Foundation of China under Grant Nos.60578038 and 40427001
关键词 ATMOSPHERICS Optical radar Signal to noise ratio Atmospherics Optical radar Signal to noise ratio
  • 相关文献

参考文献13

  • 1E. J. Darland, G. E. Leroi, and C. G. Enke, Anal. Chem. 51,240 (1979).
  • 2D. P. Donovan, J. A. Whiteway, and A. I. Carswell, Appl. Opt. 32, 6742 (1993).
  • 3K. Omote, Nucl. Instrum. Methods Phys. Res. A 293, 582 (1990).
  • 4M. Ware, A. Migdall, J. C. Bienfang, and S. V. Polyakov, J. Mod. Opt. 54, 361 (2006).
  • 5J. W. E. van Dijk and H. W. Julius, Radiation Protection Dosimetry 84, 359 (1999).
  • 6Z.-S. Liu, D. Wu, J.-T. Liu, K.-L. Zhang, W.-B. Chen, X.-Q. Song, J. W. Hair, and C.-Y. She, Appl. Opt. 41, 7079 (2002).
  • 7J. Zhu, Y. Chen, Z. Yan, S. Wu, and Z. Liu, Chin. Opt. Lett. 6, 449 (2008).
  • 8Z. S. Liu, B. Y. Liu, Z. G. Li, Z. A. Yan, S. H. Wu, and Z. B. Sun, Appl. Phys. B 88, 327 (2007).
  • 9J. W. Miiller,Nucl. Instrum. Methods i12, 47 (1973).
  • 10D. N. Whiteman, Appl. Opt. 42, 2571 (2003).

同被引文献27

引证文献6

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部