期刊文献+

离子色谱光度法测定NO_2^-的研究 被引量:2

Study on NO_2^-Determination by Chromatography
下载PDF
导出
摘要 阐述了对水体中NO-2采用高效离子色谱分离、紫外光度检测的新方法。即在离子色谱分离柱对水体中主要阴离子进行分离的基础上,利用NO-2(包括NO-3)在紫外光区有吸收,而Cl-、SO2-4等离子在此区间无吸收的原理,有效地消除了在使用电导法检测NO-2时,由于浓度较高的Cl-和NO-2因树脂亲和力接近(保留时间相近)而产生对NO-2测定的干扰,使离子色谱法检测NO-2的适用领域大为拓宽。加标回收率为97%~102%,方法检出限(3δ)为0.0008μg/ml,相对标准偏差为1.18%。 A new method to determine NO-2 in water solution by high effective ion chromatograph separation & ultraviolet light is described.By separating the main anion in water solution by ion chromatographic separation colum,and using the principle that NO-2(including NO-3) has absorbtion while Cl- & SO2-4 ion have no absorbtion at the ultraviolet area,the interference due to the close resin affinities(almost the same retaining time) of Cl- & NO-2 with higher concentration on the NO-2 determination is eliminated with good effect,when determining NO-2 by conductometry,so that the suitable area of determining NO-2 by ion chromatograph is largely extended.The method is provided with a standard recovery of 97%~102%,a detection limit(3δ) of 0.0008 μg/ml,a relative standard deviation of 1.18% and a good linear in the concentration range from 10 μg/L ̄100 mg/L.
作者 蒋文捷
出处 《宝钢技术》 CAS 1998年第4期28-32,共5页 Baosteel Technology
关键词 离子色谱 紫外检测 硝酸根离子 光度法 Ion chromatography Ultraviolet determination NO-2
  • 相关文献

同被引文献30

  • 1陶晓秋,张新申.电导检测低压离子色谱分析过渡金属离子[J].成都科技大学学报,1996(4):18-22. 被引量:6
  • 2陈甫华,郁建栓,戴树桂.离子色谱/氢化物发生/原子吸收法测定天然淡水中的4种砷形态[J].中国环境科学,1996,16(1):77-80. 被引量:11
  • 3赵俐敏.离子色谱法同时测定水中的邻硝基苯酚、间硝基苯酚和对硝基苯酚[J].分析化学,1997,27(6):701-703.
  • 4.生活饮用水卫生规范[M].北京:中华人民共和国卫生部,2001.184-188.
  • 5.CJ/T43-2001城市供水钠、镁 钙的测定-离子色谱法城市供水水质检验方法标准及编制说明和研究报告[M].北京:中国标准出版社,2001..
  • 6.GB/T8538—1995饮用天然矿泉水检验方法.[S].北京,中国环境科学出版社,2000..
  • 7张金松 范晓军.国际饮用水水质标准[M].北京:中国建筑工业出版社,2001..
  • 8Ruben Garclia-Fernfiandez, J. Ignacio Garclia-Alonso, Alfredo Sanz-Medel. Simultaneous Determination of inorganic anions,calcium and magnesium by suppressed ion chromatography[J].J. Chromatogr. A,2004,1033,127- 133.
  • 9Kauhiko Tanaka, Kazutoku Ohtaa, Paul R. Haddadb et al. Highperformance ion-exclusion/cation-exchange chromatography of anions and cations in acid rain waters on a weakly acidic cationexchange resin[J]. J. Chromatogr. A, 2001,920,239- 245.
  • 10The California Environmental Protection Agency's Office of Environmental Health Hazard Assessment (OEHHA). OEHHA Announces Health Goal for Perchlorate in Drinking Water,March 11,2004, http://www, oehha, ca. gov.

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部