摘要 8500残采皮带巷发生突水,最大水量706 m3/h,稳定水量683 m3/h,堵水期间最大水量983 m3/h。8500皮带巷的突水对矿井的安全构成严重的威胁,由于该地点水文地质条件极为复杂,为此本次应用了地面瞬变电磁法对该地点进行了勘探,根据对勘探结果的分析,进行了布孔堵水,取得了较好的效果。 November 27,2003, water inrush occurred at 8500 residual belt, the largest water flux,706 m^3/h, the stable water flux, 683 m^3/h, during water shutoff the largest water flux 983 m^3/ h. Water inrush at 8500 residual belt makes a serious threat, because of extremely complex hydrogeological conditions. After 4 years of water shutoff, nearly one billion expended on shutoff and drainage,the effect is still not ideal, based on which Xi'an academy of sciences conduct a transient electromagnetic exploration on ground according at this site, by this data chazhuang mine disposes water shutoff pores and achieves good results.
作者 姜华
出处 《华北科技学院学报》 2009年第4期43-46,共4页 Journal of North China Institute of Science and Technology
关键词 地面 瞬变电磁 勘探 堵水 水文地质条件 ground transient electromagnetic exploration water shutoff hydrogeological conditions
  • 相关文献

参考文献6

二级参考文献51

  • 1傅良魁,孟海东,宋宇辰.激发极化法找水的一些新进展[J].物探与化探,1993,17(6):435-440. 被引量:14
  • 2李金铭.电法勘探方法发展概况[J].物探与化探,1996,20(4):250-258. 被引量:97
  • 3谢捷生.时间域激发极化法寻找地下水方法及测量仪器[J].国外地质勘探技术,1996(3):1-6. 被引量:4
  • 4方文藻 李予国 等.瞬变电磁测深法原理[M].西安:西北工业大学出版社,1993.15-18.
  • 5何樵登.地震勘探原理及方法[M].北京:地质出版社,1986..
  • 6柯樵登.地震勘探原理及方法[M].北京:地质出版社,1986..
  • 7中华人民共和国地质矿产部.中国鄂尔多斯盆地北部-中日合作地震勘探综合解释总结报告[M].北京:地质出版社,1988..
  • 8中国科学院黄土综合科学考察队.黄土高原地区自然环境及其演变[M].北京:科学出版社,1991..
  • 9中国科学院黄土综合科学考察队.黄土高原地区水资源问题及其对策[M].北京:中国科学技术出版社,1991..
  • 10中国科学院黄土综合科学考察队.贡土高原地区地下水资源合理利用[M].中国科学技术出版社,1991..

共引文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部