激光小梁成形术前后对原发性开角型青光眼患者昼夜眼压变化影响 被引量:1

Intraocular pressure alterations around selective laser trabeculoplasty in primary open-angle glaucoma patients
原文传递
导出
摘要 目的评价选择性激光小梁成形术(SelectivelaserTrabeculoplastySLT)对原发性开角型青光眼(primaryopen—angleglaucoma,POAG)昼夜眼压的影响。方法POAG患者40例76只眼。倍频Q-开关532nmNdYAG激光,3ns单脉冲,光斑直径400μm,激光击射下方180。范围小梁组织,能量0.53~0.89mJ,点数60~100点。气动眼压计测量术前及术后12周昼夜眼压,两组数值比较采用配对t检验。结果术前平均眼压(21.6±2.87)mmHg(1mmHg-0.133KPa),术后平均眼压(18.7±1.36)mmHg,两组比较P〈0.05(t=7.69);手术前后6am点术眼眼压降低最明显,为6.9mmHg。术前眼压高峰出现在6am,波谷最低在10pm,昼夜眼压波动6.4mmHg;术后眼压高峰移至12时,最低在22时,昼夜眼压波动3.2mmHg。结论SLT治疗原发性开角型青光眼安全、可靠,可有效降低POAG患者的平均眼内压,降低昼夜眼压波动。 Objective To evaluate the influence on intraocular pressure of primary open-angle glaucoma patients aider selective laser trabeculoplasty. Methods Forty cases (76 eyes) of POAG, multiple-frequency Q, 532nm Nd YAG 3ns single pulse laser (power 0.53-0.89mJ, 60-100 points, laser diameter 400μm) was performed to inferior 180° trabeculum tissues. The intraocular pressure pre-operation and 12 weeks post operation were detected, data was analyzed by T test. Results The average intraocular pressure was 21.6+ 2.87 mmHg (lmmHg=0.133KPa) pre-operative and 18.7±1.36mmHg post operative, there was statistically significant difference ( t=7.69, P〈0.05 ) ; lOP decreased most obviously (6.9mmHg) at 6am. The peak IOP pre-operative appeared at 6am and the lowest lOP appeared at 10pm, the change of lOP was 6.4 mmHg; the peak lOP post-operative appeared at 12am and the lowest lOP appeared at 10pm, the change of IOP was 3.2 mmHg. Conclusions SLT is a safe operation to POAG, it can decrease the mean IOP and lOP wave motion day and night effectively in POAG patients.
出处 《中国实用眼科杂志》 CSCD 北大核心 2009年第11期1291-1292,共2页 Chinese Journal of Practical Ophthalmology
关键词 选择性激光小梁成形术 原发性开角型青光眼 Primary open-angle glaucoma Selective laser trabeculoplasty
  • 相关文献

参考文献5

二级参考文献29

  • 1Best UP, Domack H, Schmidt V. Long-term results after selective laser trabeculoplasty-a clinical study on 269 eyes. Kiln Monatsbl Angenheilkd, 2005, 222 (4): 326-331.
  • 2Juzych MS, Chopra V, Banitt MR, et al. Comparison of long-term outcomes of selective laser trabeculoplasty versus argon laser trabeculoplasty in open-angle glaucoma. Ophthalmology, 2004,111 (10): 1853-1859.
  • 3Gracner T. Intraocular pressure response of capsular glaucoma and primary open-angle glaucoma to selective Nd: YAG trabeculoplasty: a prospective, comparative clinical trial. Eur J Ophthalmol, 2002, 12(4):287-292.
  • 4Hollo G. Argon and low energy, pulsed Nd: YAG laser trabeculoplasty. A prospective, comparative clinical and morphological study. Acta Ophthalmol Stand, 1996, 74 (2):126-131.
  • 5Melamed S, Pei J, Epstein DL, Short-term effect of argon laser trabeculoplasty in monkeys. Arch Ophthalmol, 1985, 103(10): 1546-1552.
  • 6Van der Zypen E, Fankhauser F, Ultrastructural changes of the trabecular meshwork of the monkey (Maeaca speciosa) following irradiation with argon laser light, Graefes Arch Clin Exp Ophthalmol, 1984, 221 (6): 249-261.
  • 7Alexander RA, Grierson I. Morphological effects of argon laser trabeculoplasty upon the glaucomatous human meshwork. Eye,1989, 3 (6): 719-726.
  • 8Latina MA, Park C. Selective targeting of trabecular meshwork cells: in vitro studies of pulsed and CW laser interactions. Exp Eye Res, 1995, 60 (4):359-371.
  • 9Mark A, Svantiago A, Dong H, et al. Q-switched 532 nm Nd:YAG laser reabeculoplasty (Selective Laser Trabeculoplasty).Ophthalomology, 1998, 105 (11): 2082-2088.
  • 10Lanzetta P, Menehini U, Virgili G. Immediate intraocular pressure to selective laser trabeculoplasty. Br J Opthalmol, 1999, 83(1): 29-32.