期刊文献+

基于LOCO的上海光源储存环线性光学参数校正(英文) 被引量:2

Linear optics correction based on LOCO at SSRF storage ring
下载PDF
导出
摘要 为了测量和校正线性光学参数,在上海光源储存环调束过程当中使用了基于响应矩阵的线性光学参数分析(LO-CO)的方法。介绍了应用LOCO进行计算和校正的过程,包括:数值模拟得到束流位置探测器的测量精度对拟合结果的影响,调整四极铁电源电流强度来校正工作点和beta函数周期性的恢复。测量结果表明,在四极铁强度调整幅度在1.5%以内的情况下,储存环的束流光学参数成功地恢复到和设计值相当接近的状态,beta函数和色散函数畸变小于1%。通过束流光学参数的校正,使得在今后的工作当中可以轻松地控制储存环的工作模式。 Linear optics from closed orbits (LOCO) has been used during the commissioning of the Shanghai Synchrotron Radiation Facility (SSRF) storage ring. The LOCO compares a model response matrix to the real machine response matrix. Using the measured response matrix of the SSRF storage ring, the gradients in all 200 quadrupole magnets were determined, and the calibration factors of steering magnets and beam position monitors (BPMs) were obtained at the same time. After adjusting the currents of quadrupole-magnet power supplies by the maximum of 1.5 %, the optics parameters were restored very close to the designed values. The horizontal and vertical differences of beta function from the design values are around 10% before correction and 1% after correction.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2009年第12期1893-1897,共5页 High Power Laser and Particle Beams
基金 Supported by Shanghai Synchrotron Radiation Facility Project
关键词 线性束流光学校正 线性光学参数分析 上海光源储存环 linear optics correction linear optics from closed orbits SSRF storage ring
  • 相关文献

参考文献3

二级参考文献26

  • 1[1]Chen S Y,Xu H J,Zhao Z T.Shanghai Synchrotron Radiation Facility,PAC'99,New York,March 27-April 2,1999.
  • 2[2]Liu G M,Dai Z M,et.al.High Energy Physics and Nuclear Physics,2006,30:144-146.
  • 3[3]Winick H.Synchrotron Radiation Research,ISBN-10:0306403633,September 30,1980.
  • 4[4]Conceptual Design Report of NSLS-Ⅱ(Chapter 3 Science at NSLS-Ⅱ),2006
  • 5[5]Shenoy G,Viccaro P J.J Synchrotron Rad,2005,12:123.
  • 6[6]Sham T K.Chemical applications of synchrotron radiation ISBN 978-981-02-4480-4,981-02-4480-0(set),Jun 2002
  • 7[7]Ari I E.Applications of Synchrotron Radiation:Micro Beams in Cell Micro Biology and Medicine,(Biological and Medical Physics,Biomedical Engineering),ISBN-10:3540464247 ISBN-13:978-3540464242,April 12,2007
  • 8[8]Rack A.Synchrotron Radiation Based Imaging Methods for Industrial,DIR 2007-International Symposium on Digital industrial Radiology and Computed Tomography,June 25-27,2007,Lyon,Franc.
  • 9[9]Pantos E.Applications of Synchrotron Radiation to Archanologicai Ceramics,Modern Trends in Scientific Studies on Ancient Ceramics,BAR Internationai Series1011,2002,377-384
  • 10[1]CHEN S Y,XU H J,ZHAO Z T.Proc.SSILS,Shanghai,2001,16-20