金沉积烤瓷冠和贵金属烤瓷冠对磁共振图象的影响 被引量:3

Influence of Galvano-ceramic and Precious Metal-ceramic Crowns on Magnetic Resonance Imaging
下载PDF
导出
摘要 目的:通过对金沉积烤瓷冠和贵金属烤瓷冠在磁共振图象(MRI)中形成的金属伪影进行分析,探讨其对磁共振图象的影响。方法:采用同一个模型分别制作金沉积烤瓷冠和贵金属烤瓷冠,以及作为对照组的树脂全冠。将样本按照制作的材料分为GA组;BioKC97组;SP-78组;Bio98组和作为对照的RE组。所有的样品置于蒸馏水中进行MRI三种不同序列(T1,T2加权相回波和梯度序列)扫描,通过软件分析获取样本周围蒸馏水信号强度(500mm2)的平均值和标准差。结果:GA组与RE组之间无差异;BioKC97组与RE组在3个序列中均有显著性差异(P=0.000);SP-78组;Bio98组与RE组仅在梯度序列中有显著性差异(P=0.000)。结论:金沉积烤瓷冠没有在MRI中形成金属伪影,对MRI没有影响,而贵金属烤瓷冠对MRI有一定的影响。 Objective : To evaluate the artifacts from galvano - ceramic and precious metal - ceramic crowns in magnetic resonance imaging (MRI). Methods : Galvano - ceramic and metal - ceramic crowns ( Group BioKC97, SP - 78, Bio98 ) were fabricated with the same model. All materials were imaged by means of 1.5T MRI apparatus with three different sequences (T1 -weighted spin- echo, T2- weighted spinecho and Gradient echo). Mean and Standard deviation of distilled water signal intensity (SI) around the sample in the region of interest (500 mm) enclosing the whole artifacts was determined, and compared for evaluation of the homogeneity of SI. Results : There was statistical difference in the SI between acrylic resin control and BioKC97 in the three sequences (P =0.000). The mean SI for Bio98 and SP- 78 were significantly different from that of acrylic resin control (RE) in GE sequence ( P = 0. 000). No difference was showed between acrylic resin control and galvano - ceramic crown. Conclusion : Within the limitations of this in - vitro study, galvano - ceramic crown does not cause artifact in the MRI. However, precious metal - ceramic crowns cause moderate artifacts in the MRI.
出处 《口腔医学研究》 CAS CSCD 北大核心 2009年第5期622-624,共3页 Journal of Oral Science Research
关键词 磁共振图象 金沉积烤瓷冠 贵金属烤瓷冠 金属伪影 Magnetic resonance imaging Galvano - ceramic Metal - ceramic Artifact
  • 相关文献

参考文献12

  • 1Masumi S,Arita M,Morikawa M,et al.Effect of dental metals on magnetic resonance imaging[J].J Oral Rehabil,1993,20(1):97-106.
  • 2Bui FM,Bott K,Mintchev MP.A quantitative study of the pixel-shifting,blurring and nonlinear distortions in MRI images caused by the presence of metal implants[J].J Med Eng Technol,2000,24:20-27.
  • 3Hinshaw DB,Holshouser BA,Engstrom HI,et al.Dental material artifacts on MR images[J].Radiology,1988,166 (3):777-779.
  • 4Shafiei F,Honda E,Takahashi H,et al.Artifacts from dental casting alloys in magnetic resonance imaging[J].J Dent Res,2003,82 (8):602-606.
  • 5Setz J,Diehl J,Weber H.The marginal fit of cemented galvano-ceramic crowns[J].Int J Prosthodont,1989,2:61.
  • 6Weishaupt P,Bernimoulin JP,Lange KP,et al.Clinical and inflammatory effects of galvano-ceramic and metal-ceramic crowns on periodontal tissues[J].J Oral Rehabil,2007,34(12):941-947.
  • 7Krieg G.Erste Langzeitergebnisse galvanokeramischer Kronen nach dem AGC-Verfahren.Eine 9-Jahres-Studie[J].Quintessenz,1995,46:783.
  • 8Vikhoff B,Ribbelin S,K hler B,et al.Artefacts caused by dental filling materials in MR imaging[J].Acta Radiol,1995,36(3):323-325.
  • 9Hashemi RH,Bradley WG Jr.MRI:the basics.Baltimore:Williams & Wilkins.1997.1st ed.
  • 10Viano AM,Gronemeyer SA,Haliloglu M,et al.Improved MR imaging for patients with metallic implants[J].Magn Reson Imaging,2000,18:287-295.

同被引文献34

  • 1孙樱林,刘玉华.镍铬合金固定修复体对MRI影像的影响[J].现代口腔医学杂志,2007,21(1):72-74. 被引量:17
  • 2Abbaszadeh K, Heffez LB, Mafee MF. Effect of interference of metallic objects on interpretation of T1- weighted magnetic resonance images in the maxillofacial region [J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2000, 89(6):759-- 65.
  • 3Hana hHubdlkovd, Paola La Serna, Lo Linetskiy. Dental alloys and magnetic resonance imaging [J]. Int Dent J, 2006, 56 : 135--141.
  • 4Destine D, Mizutani H, Igarashi Y. Metallic artifacts in MRI caused by dental alloys and magnetic keeper [J]. Nihon Hotetsu Shika Gakkai Zasshi, 2008, 52(2) : 205-10.
  • 5Shafiei F, Honda E, Takahashi H, Sasaki T. Artifacts from dental casting alloys in magnetic resonance imaging [J]. J Dent Res, 2003, 82(8):602-6.
  • 6Vaccaro AR, Chesnut RM, Seuderi G, et al. Metallic spinal artifacts in magnetic resonance imaging [J]. Spine, 1994, 19 (11) : 1237-42.
  • 7Costa ALF, Aeenzeller S, Yasuda CL, et al. Artufacts in brain magnetic resonance imaging due to metallic dental objects [J]. Med Oral Patol Oral Vir Bueal, 2009, 14(6) : 278-82.
  • 8Gray CF, Redpath TW, Smith FW. Pre--surgical dental implant assessment by magnetic resonance imaging[J].J Oral Implantol, 1996, 22(2) : 147-53.
  • 9Abbaszadeh K, Heffez LB,Mafee MF.Effect of interference of metallic objects on interpretation of Tl-weighted magnetic resonance images in the maxillofacial region [J].Oral Surg Oral Med Oral Pathol Oral Radiol Endod,2000,89 (6): 759-765.
  • 10Shafiei F,Honda E,Takahashi H,et al.Artifacts from dental casting alloys in magnetic resonance imaging [J].J Dent Res,2003,82(8):602-606.

引证文献3

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部