多接收电感耦合等离子体质谱法精确测量铀中痕量钚同位素方法研究 被引量:9

Studies on the Precise Measurement of Isotope of Trace Plutonium in Uranium by MC-ICP-MS
下载PDF
导出
摘要 经过核燃料后处理得到的铀产品中含有极微量钚杂质,对其同位素组成进行分析有利于对应铀材料的溯源。本工作在铀钚化学分离的基础上,对影响MC-ICP-MS法精确测量痕量钚同位素丰度比值的仪器条件进行了优化,研究了仪器分辨率、离子提取模式的选择、"背景和干扰"等参数的影响,探索研究了MC-ICP-MS上质量偏倚的校正方法。对选择的两个后处理铀产品中痕量钚同位素比进行了测量,当铀钚比例达1010时,测得的239Pu/240Pu相对不确定度优于5%。并且建立了在MC-ICP-MS上测量ng.L-1量级钚同位素丰度比值的方法。 The infinitesimal plutonium impurity was contained in the uranium product obtained by reproeessing. The precise measurement of the isotope ratio of plutonium was beneficial to the identification of the corresponding source of uranium product. Basing on the separation of trace plutonium from uranium matrix, the operating parameters of MC-ICP-MS were studied and optimized for determining the isotope ratio of trace plutonium, such as the adjustment of resolution, selection of mode of ion extraction, elimination of background and interference, etc. The correction method of the mass discrimination was explored for MCICP-MS measuring isotope ratio. The isotope ratio of 239pu/240 Pu in two selected uranium products obtained by reprocessing, which was measured and corrected by measuring plutonium reference material. The ratio of uranium and plutonium is more than 10^10, and the sum of relative uncertainty for plutonium measurement is better than 5%. The measuring method of isotope ratiois establishes for ng ·L^-1 level of plutonium.
出处 《质谱学报》 EI CAS CSCD 2009年第6期327-333,共7页 Journal of Chinese Mass Spectrometry Society
关键词 痕量钚 MC-ICP—MS 测量 uranium trace plutonium MC-ICP-MS measurement
  • 相关文献

参考文献8

  • 1HERTLE H. Multi-collector ICP-MS for high precision isotope ratio measurements: application to isotopic dating methods [R]. IAEA-CN-80/14P: 437-438.
  • 2TAYLOR R N, WARNEKE T, MILTON J A, et al. Multiple ion counting determination of plutonium isotope ratios using multi-collector ICP-MS [J]. Journal of Analytical Atomic Spectrometry, 2003,18 : 480-484.
  • 3李力力,李金英,赵永刚,张继龙,王同兴.铀基体中痕量钚的分离[J].核化学与放射化学,2007,29(3):135-140. 被引量:4
  • 4李力力,李金英,赵永刚,刘峻岭,张继龙.多接收电感耦合等离子体质谱法对铀同位素丰度的测定[J].核化学与放射化学,2006,28(3):152-156. 被引量:5
  • 5STURUP S, DAHLGAARD H, NIELSEN S C. High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samples[J]. Journal of Analytical Atomic Spectrometry,1998,13;1 321-1 326.
  • 6金玉仁,章连众,韩世钧,朱凤蓉,白峻峰,周国庆,马锋,张利兴.萃取色层分离同位素稀释ICP-MS测定空气中费克量钚[J].化学学报,2000,58(10):1291-1295. 被引量:14
  • 7TAYLOR R N, WARNEKE T, MILTON J A, et al. Plutonium isotope ratio analysis at femtogram to nanogram levels by multicollector ICP-MS[J]. Journal of Analytical Atomic Spectrometry, 2001, 16:279-284.
  • 8CHIAPPINI R, TAILADE J M, BREBION So Development of a high-sensitivity inductively coupled plasma mass spectrometer for actinide measurement in the femtogrm range [J]. Journal of Analytical Atomic Spectrometry, 1996,11 : 497-503.

二级参考文献14

  • 1金玉仁,第3届环境放射化学会议录,1999年,148页
  • 2Jin Qixing,超铀元素分析,1977年,13页
  • 3WB,国家标准GB8703-83
  • 4Bem H,Ryan D E.Determination of Seven Trace Elements in Natural Waters by Neutron Activation Analysis After Preconcentration With 1-(2-Pyridylazo)-2-Naphthol[J].Anal Chim Acta,1984,166:189.
  • 5Fleissner J G.Source of Measurement Error in Plutonium Solids Isotope Assay Measurements[c]∥ Third International Conference on Facility Operations-Safeguards Interface,San Diego,California.November 29-December,1987.La Grange Park,Illinois:American Nuclear Society,1988:306-311.
  • 6Holland G,Tanner S.Plasma Source Mass Spectrometry:the New Millennium[J].Cambridge:Royal Society of Chemistry,2001:165-176.
  • 7Taylor H E.Inductively Coupled Plasma Mass Spectrometry Practices and Techniques[M].San Diego:Academic Press,2001:30-54.
  • 8Becker J S.ICP-MS:Determination of Long-Lived Radionuclides[J].Spetroscopy Europe,2002,6:8-16.
  • 9Cooley J N,Kuhn E,Donohue D L.Proceedings of IAEA Symposium on International Safeguards,IAEA-SM-351/182[R].Vienna,Austria:IAEA,13-17,Oct.1997.
  • 10Nishimura H,Magara M,Oda T,et al.Proceedings of IAEA Symposium on International Safeguards,IAEA-SM-351/98[R].Vienna,Austria:IAEA,13-17,Oct.1997.

共引文献19

同被引文献116

引证文献9

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部