介绍了串联型有源电力滤波器的基本工作原理,研究了基于三相瞬时无功功率理论的谐波电压检测方法,并分析了系统主要参数的选取方法,最后结合检测负载谐波电压控制方式用Matlab/Simulink搭建了系统的仿真模型.仿真结果验证了在合理的参数配置下,串联型有源电力滤波器可对电压型谐波能进行较好的补偿,使得电源电流的畸变减小.
This paper presents the basic operation principle and the harmonic voltage detecting method based on 3 phase instantaneous reactive power theory. The circuit parameter selection method is analyzed. Finally using the Matlab/Simulink software (mainly the toolbox PowerSystem Blockset), a simulation system of series active power filter with the control scheme of detecting the load harmonic voltage method is built. In the end, a result is given to show that the series active power filter can compensate the voltage type harmonic source correctly and feasibly and reduce aberrance of current under proper parameter configuration.
出处
《应用科技》
CAS
2009年第10期38-43,共6页
Applied Science and Technology