期刊文献+

正交试验方法在CFB锅炉燃烧调整试验中的应用 被引量:11

ORTHOGONAL TEST METHOD AND ITS APPLICATION IN COMBUSTION ADJUSTING TEST OF CFB BOILERS
下载PDF
导出
摘要 采用正交试验方法开展CFB锅炉的燃烧优化调整试验,详述了以此方法所完成的秦皇岛秦热发电有限公司5号300 MW CFB锅炉燃烧优化调整试验的情况。实际应用结果表明,正交试验方法对于CFB锅炉燃烧优化调整是一种十分有效的工具,采用该方法,可通过较少的试验工况,获得锅炉最优的运行参数。 The combustion adjusting test for combustion optimization in CFB boiler has been carried out by adopting the orthogonal test method. The situation of adjusting test for combustion optimization in CFB boiler no. 5 of 300 MW unit in Qinhuangdao Qinre Power Generation Co Ltd,completed by using orthogonal test method, has been presented. Results of practical application show that the said test method is a very effective tool for combustion optimization of CFB boilers. Adopting said method, the optimal operation parameters can be obtained through fewer test conditions.
出处 《热力发电》 CAS 北大核心 2009年第11期61-69,共9页 Thermal Power Generation
关键词 正交试验 循环流化床(CFB)锅炉 燃烧调整 300 MW机组 orthogonal test method CFB boiler combustion adjusting 300 MW unit
  • 相关文献

参考文献2

  • 1吕海生,等.秦皇岛秦热发电有限责任公司5号锅炉冷态试验及燃烧调整试验技术报告[R].西安热工研究院试验报告,2008.
  • 2张敏,王鹏利,肖平,等.循环流化床锅炉性能试验规程[M].中国电力出版社,2005.