期刊文献+

不同颈缘弯曲度和肩台形态的泽康全瓷冠的精度

Marginal fit of Cercon all-ceramic CAD/CAM crowns with different finish line curvature and margin
下载PDF
导出
摘要 目的调查不同颈缘弯曲度和肩台形态的泽康CAD/CAM全瓷冠的边缘精度。方法准备6种不同形态的基牙(弯曲度:1mm,3mm,5mm;肩台外形:圆弧肩台,直角肩台)。制作30个泽康CAD/CAM全瓷冠(每种肩台各5个),测定陶瓷基底冠和全瓷冠的边缘缝隙。采用双因子ANOVA分析后用T检验测定有无统计学差异。结果弯曲度1mm,3mm,5mm圆弧肩台的泽康全瓷冠的边缘缝隙分别为51(21)μm,53(22)μm,54(20)μm。弯曲度1mm,3mm,5mm直角肩台的泽康全瓷冠的边缘缝隙分别为49(18)μm,51(19)μm,50(22)μm。统计结果显示6种基牙之间没有显著性差异。结论泽康全瓷冠有良好的边缘精度,颈缘弯曲度和肩台形态对泽康全瓷冠的边缘精度没有显著影响。 Objective To evaluate the marginal fit of Cercon all - ceramic CAD/CAM crowns with different finish line curvature and margin in vitro. Methods Six groups of abutments (finish line curvature: linm, 3mm and 5mm, margin shape: chamfer and shoulder) were prepared. Thirty all -ceramic crowns were fabricated (five for each group). The marginal gaps of copings and veneered crowns were measured respectively. The data were calculated and analyzed with two - way ANOVA and Tukey HSD test (α = 0.05 ). Results The mean marginal gaps and their standard difference (SD) of veneered crowns for lmm, 3mm and 5mm - curvature- chamfer were 51 and 21μm, 53 and 22μm, 54 and 20μm respectively. The mean marginal gaps and their SD of veneered crowns for lmm, 3mm and 5mm - curvature - shoulder were 49 and 18μm, 51 and 19μm, and 50 and 22μm respectively. There was no significant difference on the marginal gaps among six groups of abutments. Conclusion The marginal gaps of Cercon all - ceramic crowns were within the range of clinically acceptable values. The abutment finish line curvature and shape had no significant influence on the marginal fit of Cereon all - ceramic crowns.
出处 《现代口腔医学杂志》 CAS CSCD 2009年第6期600-603,共4页 Journal of Modern Stomatology
关键词 边缘精度 泽康全瓷冠 颈缘弯曲度 肩台形态 Marginal fit All -ceramic crowns CAD/CAM Finish line
  • 相关文献

参考文献21

  • 1Mclean JW. New dental ceramics and esthetics. J Esthet Dent, 1995,7:141 - 149.
  • 2Kelly JR, Nishimura I, Campbell SD. Ceramics in dentistry: historical roots and current perspectives. J Prosthet Dent, 1996, 75: 18 -32.
  • 3Crispin BJ, Seghi RR, Globe H. Effect of different metal ceramic alloys on the color of opaque and dentin ceramic. J Prosthet Dent, 1991,65:351 -356.
  • 4Bindl A, Mormann WH. An up to 5 - years clinical evaluation of posterior IN - Ceramic CAD/CAM core crowns, Int J Prosthodont, 2002, 15 : 451 -456.
  • 5Pittayaehawan P, McDonald A, Petrie A, et al. The biaxial flexural strength and fatigue property of Lava Y - TZP dental ceramic. Dent Mater, 2007, 23 : 1018 - 1029.
  • 6Studart AR, Filser F, Kocher P, et al. Cyclic fatigue in water of veneer - framework composites for all - ceramic dental bridges. Dent Mater, 2007, 23 : 177 - 185.
  • 7Aboushelib MN, Jaqer N, Kleverlaan CL, et al. Effect of loading method on the fracture mechanics of two layered all - ceramic restorative system. Dent Mater, 2007, 23:952-959.
  • 8Pera P, Gilodi S, Bassi F, et al. In vitro marginal adaptation of alumina porcelain ceramic crowns. J Prosthet Dent, 1994, 72:585 - 590.
  • 9Rinke S, Huls A, Jahn L. Marginal accuracy and fracture strength of conventional and copy - milled all - ceramic crowns. Int J Prosthodont, 1995, 8:303-310.
  • 10Jacobs MS, Windeler AS. An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent, 1991, 65:436 - 442.