Flow Fields with Vortex in a Small Semi-open Axial Fan
原文传递
导出
摘要 In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in asmall semi-open axial fan, the experimental investigation was carried out. The tip diameter of test fan rotor was180mm and test TC sizes were lmm (TC=1mm) and 4mm (TC=4mm). Fan characteristics tests were carried outfor two cases of TC size and three-dimensional velocity fields at rotor outlet were measured using a single slanthot-wire probe at four flow-rate conditions. As a result, it was found that the pressure - flow-rate characteristicscurves for two cases showed almost the same tendency. However, the ensemble averaged velocity profiles alongradial measurement stations of TC=4mm largely changed compared with that of TC=lmm in cases of smallflow-rate condition. From the phase-locked averaging results, it was also found that the vortex existed in the rotoroutlet flow field of high flow-rate condition for each TC case. Compared with the vortices for TC=1mm andTC=4mm, the vortex for TC=4mm was stronger than that for TC=1mm. In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of test fan rotor was 180mm and test TC sizes were lmm (TC=1mm) and 4mm (TC=4mm). Fan characteristics tests were carried out for two cases of TC size and three-dimensional velocity fields at rotor outlet were measured using a single slant hot-wire probe at four flow-rate conditions. As a result, it was found that the pressure - flow-rate characteristics curves for two cases showed almost the same tendency. However, the ensemble averaged velocity profiles along radial measurement stations of TC-4mm largely changed compared with that of TC=1mm in cases of small flow-rate condition. From the phase-locked averaging results, it was also found that the vortex existed in the rotor outlet flow field of high flow-rate condition for each TC case. Compared with the vortices for TC=1mm and TC=4mm, the vortex for TC=4mm was stronger than that for TC=1mm.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2009年第4期294-300,共7页 热科学学报(英文版)
关键词 轴流风机 半开放式 流场 压力-流量特性 转子出口 技术合作 三维速度场 fan, semi-open type, vortex, tip clearance
  • 相关文献

参考文献4

  • 1Inoue M., Kuroumaru M., and Furukawa M.: Behavior of Tip Leakage Flow Behind an Axial Compressor Rotor, Trans. ASME, Journal of Engineering for Gas Turbines and Power, Vol. 108, pp.7-14, (1986).
  • 2Lakshminarayana B., Zaccaria M., and Marathe B.: The Structure of Tip Clearance How in Axial Flow Compressors, Trans. ASME, Journal of Turbomachinery, Vol. 117, pp.336-347, (1995).
  • 3Furukawa M., Inoue M., Saiki K., Yamada M.: The Role of Tip Leakage Vortex Breakdown in Compressor Rotor Aerodynamics, Trans. ASME Journal of Turbomachinery, Vol. 121, pp.469--480, (1999).
  • 4Fukano T, Fukuhara M., Kawagoe K., Hara Y. and Kinoshita K.: Experimental Study on the Noise Reduction of a Propeller Fan (lst Report, Aerodynamic Characteristics), Trans. JSME, 56-531, B, pp.3378-3382, (1990) (in Japanese).

同被引文献49

引证文献12

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部