腰椎后路非融合技术生物力学研究进展 被引量:2

Advances in biomechanics of posterior non-fusion technologies in lumbar spine
下载PDF
导出
摘要 为避免融合术后相邻节段退变的问题,腰椎后路非融合技术相继出现并得到快速发展,但在临床应用时间较短,相关基础研究尚不充分。本文总结了当前对腰椎后路非融合固定器械的生物力学评价,包括其对腰椎的活动度、椎间盘内压力、腰椎小关节的影响,以及相应的生物力学研究方法,指出后路非融合技术可以用于治疗退变性腰椎疾患,有着很好的发展前景.同时,还有很多方面需要进一步深入研究的问题。 In order to avoid the adjacent segment disease resulted from spine fusion,the concept of non-fusion technology arose and is becoming popular.The posterior non-fusion devices in lumbar spine have used clinically,but no long-term follow-up data about these devices is reported,and the basic study is not enough.We reviewed the biomechanical evaluation about posterior non-fusion technologies in lumbar spine,including range of motion,intradiscal pressure,facet joints and the biomechanical methods.We found these non-fusion technologies have advantages in treating lumbar degenerative diseases,but more deep study needs to be done.
出处 《医用生物力学》 EI CAS CSCD 2009年第5期390-394,共5页 Journal of Medical Biomechanics
关键词 生物力学 腰椎 非融合 后路器械 Biomechanics Lumbar spine Non-fusion Posterior device
  • 相关文献

参考文献16

  • 1Lindsey DP, Derek PL, Kyle ES, Paul F, et al. The Effects of an Interspinous Implant on the Kinematics of the Instrumented and Adjacent Levels in the Lumbar Spine[J]. SPINE, 2003, 28( 19):2192-2197.
  • 2Fuchs P D, Derek PL, Ken YH, et al. The Use of an Interspinous Implant in Conjunction With a Graded Facetectomy Procedure [ J ]. SPINE2005,30 ( 11 ) :1266-1272.
  • 3Schulte TL, Hurschler C, Haversath M, et al. The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression [J]. Eur Spine J 2008,17(8):1057-1065.
  • 4Tsai, K J, Murakami H, Lowery GL,et al. A biomechanical evaluation of an interspinous device (Coflex) used to stabilize the lumbar spine [J]. J-Surg-Orthop-Adv, 2006, 15(3): 167-72.
  • 5Wilke H J, Hendrik S, Karin W, et al. Biomechanical Evaluation of a New Total Posterior-Element Replacement System [J]. SPINE 2006, 31 (24) : 2790-2796.
  • 6Zhu Q, Chad RL, Simon GS, et al. Biomechanical Evaluation of the Total Facet Arthroplasty Systam^TM: 3-Dimensional Kinematics [ J ]. SPINE2007, 32(1 ):55-62.
  • 7Wilke HJJ, Drumm K, Haussler C, etal. Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure[J]. Eur Spine J, 2008, 17 (8): 1049-1056.
  • 8Swanson KE, Derek PL, Ken YH, et al. The Effects of an Interspinous Implant on Intervertebral Disc Pressures [ J]. SPINE,2003,28(1 ):26-32.
  • 9Schmoelz W, Huber JF, Nydegger T, et al. Influence of a dynamic stabilisation system on load bearing of a bridged disc: an in vitro study of intradiscal pressure [ J ]. Eur Spine J, 2006, 15 (8): 1276-1285.
  • 10Chan SS, Seoung WP, Lee SH. Biomechanical Evaluation of an Interspinous Stabilizing Device, Locker [ J ]. SPINE2008,33(22): E820-E827.

同被引文献50

  • 1费琦,邱贵兴,王以朋.腰椎棘突间内固定的应用进展[J].中国骨与关节外科,2008,1(3):245-250. 被引量:4
  • 2吴浩波,严世贵,陈其昕,余世策.不同运动负荷下腰椎应力的三维非线性有限元分析[J].中国运动医学杂志,2004,23(5):480-484. 被引量:14
  • 3胡新佳,李康华.腰椎间盘切除与人工椎间盘置换前后上位关节突关节内压力改变[J].中国修复重建外科杂志,2005,19(6):427-430. 被引量:8
  • 4徐力鹏,肖进,张美超,原林.腰椎小关节承载功能的三维有限元分析[J].创伤外科杂志,2006,8(2):140-143. 被引量:5
  • 5Puentedura E J, Landers MR, Cle|and JA, et al. Thoracic spine thrust manipulation versus cervical spine thrust ma- nipulation in patients with acute neck pain:a randomized clinical trial [ J ]. J Orthop Sports Phys Ther, 2011,41 ( 4 ) : 208 - 220.
  • 6Saavedra-HernOndez M, Ssavedra-Heru6ndez M, Castro- S6nchez AM, et al. Predictors for identifying patients with mechanical neck pain who are likely to achieve short - term success with manipulative interventions directed at the cervi- cal and thoracic spine [ J ]. J Manipulative Physiol Ther, 2011,34(3) :144 - 152.
  • 7Cleland JA, Fritz JM, Kulig K, et al. Comparison of the ef- fectiveness of three manual physical therapy techniques in a subgroup of patients with low back pain who satisfy a clini- cal prediction rule: a randomized clinical trial [ J ]. Spine ( Phila Pa 1976 ), 2009,34 ( 25 ) : 2720 - 2729.
  • 8Henderson CN. The basis for spinal manipulation:chiroprac- tic perspective of indications and theory [ J ]. J Electromyogr Kinesiol,2012,22 (5) :632 - 642.
  • 9Keller TS, Colloca C J, B61iveau JG. Force - deformation re- sponse of the lumbar spine: a sagittal plane model of pos- teroanterior manipulation and mobilization [ J ]. Clin Bio- mech ( Bristol, Avon) ,2002,17 ( 3 ) : 185 - 196.
  • 10李康华,肖文峰,胡建中,雷光华.人工腰椎间盘置换后下位关节突关节内压力的变化[J].中国组织工程研究与临床康复,2008,12(4):631-634. 被引量:6

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部