摘要
文中对配水泵房的工艺改造原因及必须注意的问题作了详细分析,对于中小城市的配水泵房宜设计成半地下式,配水泵采用自灌式供水方式,这样可随时启动水泵,保证迅速安全供水.
The reasons for technological improvement of water distribution pump house are studied and the key problems are analyzed.For those medium and small cities ,semi-under- ground structure should be adopted for water distribution pump house and self-priming water supply should be used for water-feeding pump so that the pump could be started whenever necessary to ensure rapid and safe water supply.
关键词
配水泵房
配水泵
自灌式供水
安装高度
water distribution pump house
water-feeding pump
self-priming water supply
maximum installation height of pump