摘要
对华电能源股份有限公司牡丹江第二发电厂#6机组连通管式汽包双色云母水位计产生偏差的原因进行了分析,针对影响水位计显示值的因素提出了水位测量系统的改造措施。
The reasons,which caused the deviation of the connected tube type two color mica water gauge of #6 unit steam drum in Mudanjiang Second Power Plant of Huadian Energy Source Corporation Limited,were analyzed.Aiming at the factors influencing the indicated value of the water gauge,the water level measurement system reformation measures were put forward.
出处
《华电技术》
CAS
2009年第11期12-14,共3页
HUADIAN TECHNOLOGY
关键词
汽包
水位计
偏差
改造
steam drum
water level indicator
deviation
reformation