华东地区双层幕墙冬季的CFD热工模拟计算 被引量:1

Thermal Calculation for a Winter Double Skin Facade in East China with CFD Simulation
下载PDF
导出
摘要 应用CFD技术对华东地区某双层幕墙冬季时的传热特性进行了分析,采用层流模型对热通道的温度场和速度场进行了模拟,最终得出双层幕墙的综合传热系数K和冬季保温增热效果,计算结果表明该双层幕墙系统在冬季运行时具有良好的节能效果。 CFD techniques were used to analyzed the thermal performance for a winter double skin facade in East China. Laminar model was chosen to simulate the temperature field and flow field of the thermal cavity. Integrated thermal coefficient K and the value of heat preservation and increase were finally calculated. The numerical results showed that the facade system could reach excellent energy-saving performance in winter.
出处 《广东土木与建筑》 2009年第9期55-57,共3页 Guangdong Architecture Civil Engineering
关键词 双层幕墙 CFD 综合传热系数 保温增热 double skin facade CFD integrate heat transfer coefficient heat preservation and increase
  • 相关文献

参考文献2

二级参考文献11

  • 1陈海,姜清海,郭金基,张开成,张镇成,崔传芹.双层通风幕墙热气流有限分析计算方法的研究[J].中山大学学报(自然科学版),2005,44(1):34-37. 被引量:16
  • 2江宏俊.流体力学[M].北京:高等教育出版社,1988.230-234.
  • 3Guohui Gan. Thermal transmittance of multiple glazing:computational fluid dynamics prediction[J]. Applied Thermal Engineering 2001, (21) 1583-1592.
  • 4M.A. Bernier, B. Bourret, Effects of glass plate curvature on the U-factor of sealed insulated glazing units[J]. ASHRAE Transactions 1997, 103 (1):270-277.
  • 5M.G. Hutchins, W J Platzer. Thermal performance of advanced g]azing materials[J].Renewable Energy 1996,8(1): 540-545.
  • 6J A Clarke, M Janak, P . Puyssevelt, Assessing the overall performance of advanced glazing systems[J].Solar Energy 1998, 63(4) :231-241.
  • 7郭金基.变截面开口薄壁杆件的有限分析法[J].中山大学学报:自然科学版,1985,24(4):39-50.
  • 8叶歆.建筑热环境[M].北京:清华大学出版社,1995..
  • 9JCJ 35-87 建筑气象参数标准
  • 10GB 50178-93 建筑气候区别标准[S]

共引文献20

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部