期刊文献+

A honeycomb-tube packing medium and its application to column flotation 被引量:1

A honeycomb-tube packing medium and its application to column flotation
下载PDF
导出
摘要 We address problems in the development of large-scale flotation columns that use short cylinders. As a starting point, we investigated the packing medium to identify a highly efficient internal packing for the flotation column. The chosen packing was a honeycomb structure with an aperture diameter of 80 mm, a web thickness of 0.80 mm, a film height of 1000 mm, packed into a 400 mm diameter space, which completely filled the vessel at optimal cost. The column consisted of a modular ring of single-hole hexagonal honeycomb tube packing made from atactic polyproplene (PP-R). The packing was tested in a cyclonic, static micro-bubble flotation column. Computational fluid dynamic modeling was used to analyze the flotation fluid in a honeycomb tube packed flotation column. Our results show that the fluid axial movement was maximized and that the transverse fluid velocities were zero in the vicinity of axial flow. Using the honeycomb tube packing for copper sulfide flotation we observed that the average concentration in the product was increased to 25.41%, from an average feed concentration of 0.729%, with an average recovery of 92.92%. The demands of on-site industrial production were met. We address problems in the development of large-scale flotation columns that use short cylinders. As a starting point, we investigated the packing medium to identify a highly efficient internal packing for the flotation column. The chosen packing was a honeycomb structure with an aperture diameter of 80 mm, a web thickness of 0.80 mm, a film height of 1000 mm, packed into a 400 mm diameter space, which completely filled the vessel at optimal cost. The column consisted of a modular ring of single-hole hexagonal honeycomb tube packing made from atactic polyproplene (PP-R). The packing was tested in a cyclonic, static micro-bubble flotation column. Computational fluid dynamic modeling was used to analyze the flotation fluid in a honeycomb tube packed flotation column. Our results show that the fluid axial movement was maximized and that the transverse fluid velocities were zero in the vicinity of axial flow. Using the honeycomb tube packing for copper sulfide flotation we observed that the average concentration in the product was increased to 25.41%, from an average feed concentration of 0.729%, with an average recovery of 92.92%. The demands of on-site industrial production were met.
出处 《Mining Science and Technology》 EI CAS 2009年第6期775-778,共4页 矿业科学技术(英文版)
基金 Project 2007AA05Z339 supported by the National High-Tech Research and Development Program of China
关键词 FILLING column flotation mineral processing 微泡浮选柱 蜂窝结构 包装 流体动力学模型 应用 介质 平均浓度 无规聚丙烯
  • 相关文献

参考文献2

二级参考文献13

共引文献28

同被引文献8

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部