为保证一等标准铂铑10-铂热电偶在使用过程中准确、可靠,需在2次溯源间隔内对其进行期间核查。介绍了一等标准铂铑10-铂热电偶核查标准的选取以及核查周期的确定,详细论述了一等标准铂铑10-铂热电偶期间核查的方法。
In order to guarantee first-class standard Platinum and Rhodium 10-Platinum thermocouple's accuracy and credibility in use, intermediate check must be done in its two trace intervals. The choice of intermediate check standard and the determination of check periodic to first-class standard Platinum and Rhodium 10-Platinum thermocouple are introduced in this paper. The method of intermediate check to first-class standard Platinum and Rhodium 10-Platinum thermocouple is discussed in detail.
出处
《江苏电机工程》
2009年第6期20-21,共2页
Jiangsu Electrical Engineering
关键词
核查标准
周期
方法
check standard
periodic
method