摘要
分析了吉林钢铁10 m2竖炉混气室顶部和预热带外炉皮钢板烧穿的原因,并介绍了采用快干防爆浇注料耐火材料进行处理的方法及使用效果。
The reasons of burning-through of gas mixing room steel top and preheating zone steel casing of vertical shaft are analyzed.The method and its performance of using rapid-drying explosion-proof refractory to repair are explained.
出处
《矿业工程》
CAS
2009年第6期28-29,共2页
Mining Engineering
关键词
竖炉
混气室顶部钢板
预热带外炉皮钢板
处理
vertical shaft
gas mixing room steel top
preheating zone steel casing
treatment