期刊文献+

计算机导航在人工全膝关节置换术中的应用 被引量:1

原文传递
导出
摘要 医学影像技术、计算机技术和空间示踪技术的发展与结合产生了计算机辅助骨科手术(CAOS),该技术亦被称为计算机手术导航。计算机导航极大地提高了人工全膝和全髋关节置换手术的准确性和可重复性。近两年,计算机导航人工全膝关节置换技术在欧美得到了较为广泛的开展,取得了很好的近期临床效果。
作者 白波
出处 《中国基层医药》 CAS 2009年第10期1913-1915,共3页 Chinese Journal of Primary Medicine and Pharmacy
  • 相关文献

参考文献22

  • 1Eric JH. Computer-assisted orthopaedic surgery a new paradigm. Tech Orthop,2003,18 (6) :221-229.
  • 2Taylor RH, Lavallee S, Burdea GC, et al. Registration for computer integrated surgery: methodology, start of the art. Computer integrated surgery. Cambridge:MIT Press, 1996,22(4) :77-97.
  • 3DiGioia AM 3rd,Jaramaz B, Colgan BD. Computer assisted orthopaedic surgery. Image guided and robotic assistive technologies. Clin Orthop Relat Res,1998,22(354) :8-16.
  • 4Bathis H, Perlick L, Tingart M, et al. Radiological results of image- based and non - image - based computer - assisted total knee arthro plasty. Int Orthop ,2004,12 (28) :87 - 90.
  • 5Whiteside LA. Soft tissue balancing: the knee. J Arthroplasty, 2002,17(4 Sup-pll ) :23-27.
  • 6Klein G R, Parvizi J, Papuri V R, et al. The effect of tibial polyethylene inserted sign on range ofmotion:evaluation ofin vivoknee kinematics by a computerized navigation system during totalknee ar- throplasty. J Arthroplasty ,2004,19 ( 8 ) :986-991.
  • 7Mahaluxmivala J,Bankes M J,Nicolai P,et al. The effect of surgeon experience on component positioning in 673 press fit condylarposterior cruciate-saerificing total knee arthroplasties. Arthroplasty,2001,16 (5) :635-640.
  • 8Mihalko W M, Boyle J, Clark L D, et al. The variability of intramedullary alignment of the femoral componentduring totalknee arthroplasty. J Arthroplasty,2005,20( 1 ) :25-28.
  • 9Haaker R G, Stockheim M, Kamp M, et al. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res,2005,12(433) :152-159.
  • 10Pandher D S, Oh K J, Boaparai R S, et al. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res, 2007,23 ( 454 ) :281-282.

同被引文献5

  • 1夏邦世,吴金华.Kappa一致性检验在检验医学研究中的应用[J].中华检验医学杂志,2006,29(1):83-84. 被引量:217
  • 2Rosati P,Bartolozzi F,Guariglia L.Intra-and interobserver repeatability of femur length measurement in early pregnancy.Ultrasound Obstet Gynecol,2004,23(6):599.
  • 3van Keulen JG,Gemke RJBJ,Polderman KH.Effect of training and strict guidelines on the reliability of risk adjustment systems in pae-diatric intensive care.Intensive Care Med,2005,31(11):1229.
  • 4Lamraski G.Monsaert A,De Maeseneer M,et al.Reliability and Validity of Plain Radiographs to Assess Angulation of Small Finger Metacarpal Neck Fractures:Human Cadaveric Study.Journal of Orthopaedic Research,2006,24(1):3745.
  • 5杨沛彦,孙俊英.股骨近端解剖参数的测量及两种髓腔形态界定方法的比较研究[J].中国医师进修杂志(外科版),2008,31(9):10-13. 被引量:1

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部