期刊文献+

新型外套管式梁柱节点多因素分析研究 被引量:19

MULTIPLE FACTOR ANALYSIS ON MECHANICAL PERFORMANCE OF OUTER-SHELL CONNECTION
原文传递
导出
摘要 在外套管式节点拟静力试验的基础上,建立该种节点有限元分析模型。经与试验数据对比,表明该有限元模型的有效性。采用有限元模型对外套管式节点进行包括外套管厚度、T型件翼缘厚度、T型件腹板厚度以及有无加劲肋的多因素分析,分析总结了这些因素对节点性能的影响。通过多因素分析,得到具有一定参考价值的结论。 Based on a quasi-static experiment of outer-shell connection (OSC), the finite element model is put forward. Compared with test data, the validity of the model is testified. Then multiple factor analysis of OSC, including the thickness of outer shell, flange plate and web plate of T-shaped members, with or without ribbed stiffeners, is carried out. And the effects of these factors on the mechanical performance of OSC are analyzed and summarized. Through multiple factor analysis, some conclusions are drawn that can provide some references for engineering practices.
出处 《工程力学》 EI CSCD 北大核心 2009年第11期60-67,共8页 Engineering Mechanics
基金 国家高技术研究发展计划(863计划)重点项目(SQ2008AA03ZX1477936)
关键词 外套管式节点 冷弯方钢管柱 低周反复荷载 有限元 多因素分析 outer-shell connection (OSC) cold-formed square tubular column low-frequency cyclic load finite element multiple factor analysis
  • 相关文献

参考文献9

二级参考文献38

  • 1林于东,林杰,宗周红.低周反复荷载作用下矩形钢管混凝土柱与钢梁连接节点的受力性能[J].地震工程与工程振动,2004,24(4):62-69. 被引量:22
  • 2李至钧,阎善章.钢管混凝土框架梁柱刚性抗震节点的试验研究[J].工业建筑,1994,24(2):8-15. 被引量:19
  • 3王来,王铁成,邓芃.方钢管混凝土框架内隔板节点抗震性能的试验研究[J].地震工程与工程振动,2005,25(1):76-80. 被引量:33
  • 4陈志华,苗纪奎.方钢管混凝土柱-H型钢梁外肋环板节点研究[J].工业建筑,2005,35(10):61-63. 被引量:18
  • 5徐云扉.低周反复荷载下两跨三层钢筋混凝土框架受力性能的试验研究[J].建筑结构学报,1986,7(2).
  • 6Yoshimura K, Kikichi K, Iuroki M. Seismic shear strengthening method for existing R/C short columns [A]. Proceedings of the Third International Conference on Steel-Concrete Composite Structures[C]. Fukuoka,Japan, 1991. 677 ~ 682.
  • 7Morino S, Kawaguchi J, Yasuzaki C, et al. behavior of concrete filled steel tubular three-dimensinal sub assemblages[A]. Composite Construc tion in Steel and Concrete Ⅱ [C]. Potosi, Missouri, 1993. 726 ~ 741.
  • 8Teraoka M, Morita K. Experimental study on structural behavior of concrete-filled square tubular column in steel H-beam connections without diaphragn[ A]. Proceeding of the 4th ASCCS International Conference on Steel-concrete Composite Structures [C]. Kosice, slovakia, 1994. 190 ~193.
  • 9Endoh K, Kosugi K, Mitsui Y. Strength of R/C flat slab-to-concrete filled steel tubular column connection [A]. Proceedings of the International Specialty Conference on Concrete Filled Steel Tubular Structures [C]. Harbin, China, 1998. 246 ~252.
  • 10Yokoyama Y, Morita K, Kawamata Y, et al. Structural behavior of steel-beam to concrete-filled square tube column connections reinforced with inner ring stiffener[A]. Proceedings of the Third International Conference on Steel-Concrete composite Structures [C]. Fukuoka, Japan, 1991.165~ 170.