期刊文献+

国产Q345钢600℃恒载升温试验研究 被引量:2

EXPERIMENTAL STUDY ON Q345 STEEL UNDER ELEVATED TEMPERATURE AND CONSTANT LOADING
下载PDF
导出
摘要 采用恒载升温试验方法,对国内10个厂家生产的Q345钢试件在600℃下进行40次有效试验,得到每批次试件在不同荷载下变形随时间的变化曲线。把试件的总变形分离为初始荷载变形、膨胀变形以及温度-荷载耦合变形3部分,并将变形曲线分成3个区间,根据变形速率的变化特点,以某一荷载下变形速率加速变大作为试件屈服的临界荷载水平,得到各批次试件在600℃的临界荷载水平为0.30~0.40。并提出保证建筑安全的前提是火灾中温度和荷载的耦合变形不超过安全值。 An experimental study on Q345 steel coming from 10 factories at 600 ℃ degree were carried out with transient tests.A series of deformation curves varing with time are obtained.The total deformation of steel was defined as sum of pre-heating deformation,thermal expansion deformation and force-temperature coupled deformation.According the characteristic of the deformation,the load value is defined as the critical load level when the speed of deform become larger.The result shows the critical load level value is between 0.30 to 0.40 at 600 ℃.In the end,a suggestion that the load-temperature coupled deformation is not allowed to excess the safety value in the fire was put forward.
出处 《钢结构》 2009年第11期84-88,共5页 Steel Construction
关键词 Q345钢 瞬态试验 临界荷载水平 Q345 steel transient test critical load level
  • 相关文献

参考文献6

二级参考文献17

  • 1蒋首超,李国强.火灾下钢结构构件的升温[J].钢结构,1996,11(2):19-24. 被引量:6
  • 2蒋首超,李国强.高温下结构钢的材料特性[J].钢结构,1996,11(2):49-57. 被引量:30
  • 3赵金城,沈祖炎.钢结构抗火分析中的材性模型[J].工业建筑,1996,26(9):3-6. 被引量:39
  • 4过镇海 时旭东.钢筋混凝土的高温性能及其计算[M].北京:清华大学出版社,2002..
  • 5CECS 200:2006.建筑钢结构防火技术规范[S].
  • 6ENV 1993-1-2 Eurocode 3.Design of steel structures Part 1.2: General/rules structural fire design[S ].
  • 7ENV 1994-1-2 Eurocode 4. Design of composite steel and concrete structures Part 1.2: structural fire design[S ].
  • 8BSI,BS 5950. Part: 8-1990, Code of practice for the fire resistance design[ S ].
  • 9AS4100-1990 Steel structures[S].
  • 10ENV 1993-1-2 Eurocode 3.Design of steel structures Part 1.2: General rules/structural fire design[ S ].

共引文献125

同被引文献12

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部