摘要
针对加氢裂化装置进料换热器结垢比较突出的情况,在对结垢机理进行研究的基础上,开发了防垢剂SFH-1和SFH-B。在375℃和390℃下实验室评价的防垢率,前者分别为89.4%和68.1%,后者为92.7%和70.4%。工业应用表明,当SFH-B加入量在100μg/g时,原料换热器出口温度可维持开工初期水平,防垢剂的防垢效果良好,且对加氢催化剂无不良影响。
Aiming at the fouling happened in the feed heat exchanger of hydrocracking unit, antifoulants SFH 1 and SFH B were developed on the basis of the fouling mechanism. The laboratory evaluation showed that the antifouling rates of the former under 375 ℃ and 390 ℃ were 89.4% and 68,1% respectively, and the latter were 92.7% and 70.4% respectively. The test result of the commercial unit showed that the SFH B antifoulant has good effect at an addition rate of 100 μg/g, the outlet temperature of the feed heat exchanger can maintain close to that of start up stage, and no side effect on the hydrotrea ting catalyst.
出处
《石油炼制与化工》
CAS
CSCD
北大核心
1998年第10期10-13,共4页
Petroleum Processing and Petrochemicals
关键词
加氢裂化装置
防垢剂
工业规模
炼油厂
hydrocracking unit, heat exchanger, antifouling agent, full scale