期刊文献+

Determination of inorganic anions in ethyl acetate by in-line hollow fiber membrane extraction with ion chromatography 被引量:1

Determination of inorganic anions in ethyl acetate by in-line hollow fiber membrane extraction with ion chromatography
下载PDF
导出
摘要 In this work, a novel hollow fiber membrane extractor was set up to extract inorganic anions from ethyl acetate using deionized water. Inorganic anions in slightly soluble organic solvents can be determined by the in-line hollow fiber membrane extractor coupled with ion chromatography at first time. Different aspects of the extraction procedure such as magnetic stirring speed, extraction flow rate and extraction time were optimized to achieve high extraction efficiency and good separation results. Satisfactory linear range, limits of detection and good repeatability were obtained. The procedure was applied to analyze inorganic anions in two commercial ethyl acetate samples. In this work, a novel hollow fiber membrane extractor was set up to extract inorganic anions from ethyl acetate using deionized water. Inorganic anions in slightly soluble organic solvents can be determined by the in-line hollow fiber membrane extractor coupled with ion chromatography at first time. Different aspects of the extraction procedure such as magnetic stirring speed, extraction flow rate and extraction time were optimized to achieve high extraction efficiency and good separation results. Satisfactory linear range, limits of detection and good repeatability were obtained. The procedure was applied to analyze inorganic anions in two commercial ethyl acetate samples.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第12期1498-1501,共4页 中国化学快报(英文版)
基金 supported by National Natural Science Foundation of China(No.20775070) by Zhejiang Provincial Natural Science Foundation of China(No.R4080124) Zhejiang Qianjiang Project of Science and Technology for Competent People(No.2008R10028).
关键词 Inorganic anions Ethyl acetate In-line hollow fiber membrane extraction Ion chromatography Inorganic anions Ethyl acetate In-line hollow fiber membrane extraction Ion chromatography
  • 相关文献

参考文献13

  • 1E. Kaiser, M.J. Wojtusik, J. Chromatogr. A 671 (2) (1994) 253.
  • 2E. Kaiser, J. Rohrer, J. Chromatogr. A 858 (2) (1999) 55.
  • 3L.E. Vanatta, J. Chromatogr. A 1213 (1) (2008) 70.
  • 4S. Pedersen-Bjergaard, K.E. Rasmussen, Anal. Chem. 71 (14) (1999) 2650.
  • 5I J. Norberg, E. Thordarson, Analyst 125 (4) (2000) 673.
  • 6I S. Muller, M. Moder, S. Schrader, P. Popp, 25th International Symposium on Capillary Chromatography, Elsevier Science Bv, Riva Del Garda, Italy, 2002, p. 99.
  • 7L.M. Zhao, M.K. Lee, Anal. Chem. 74 (12) (2002) 2486.
  • 8O.B. Jonsson, U.L. Nilsson, Anal. Bioanal. Chem. 377 (1) (2003) 182.
  • 9K. Kuosmanen, T. Hyotylalnen, K. Hartonen, M.L. Riekkola, Analyst 128 (5) (2003) 434.
  • 10C. Basheer, A. Parthiban, A. Jayaraman, H.K. Lee, S. Valiyaveettil, 25th International Symposium on Chromatography, Elsevier Science Bv, Pads, France, 2004, p. 274.

同被引文献10