摘要
对高坝洲电厂机组导轴承发生的故障进行了检查与分析,对机组上导结构进行了局部改造,其运行结果得到改善,并针对多种情况,提出了解决方案。
The inspection and analysis on the failures of the upper guide bearings of Gaobazhou hydro-generators are described.The solutions for different failures are suggested.Some components of upper guide bearings have been reformed,the operating reliability of the hydro-generators are improved.
出处
《湖北水力发电》
2009年第6期68-70,共3页
Hubei Water Power
关键词
故障
上导轴承
分析
高坝洲电厂
failure
upper guide bearing
analysis
Gaobazhou Hydropower Plant