摘要
介绍了利用便携式检测设备在不停电、不接触高压电源的情况下,对三相三线和三相四线制接线方式的电能计量装置故障及误差的检测方法和检测内容,提出了完善计算机检测管理系统的具体建议。
The detection methods and specific detection content of three-phase three-wire and three-phase four-wire electrical energy measurement device wiring fault and error are expounded under the circumstance with electricity, without access to high-voltage power supply case, and the suggestions to improve computer detection management system are put forward.
出处
《沈阳教育学院学报》
2009年第6期90-92,共3页
Journal of Shenyang College of Education
关键词
电能计量装置
故障点
误差测试
electric energy metering devices
failure point