摘要
目的了解健康成人瞬目反射正常值及其临床应用价值。方法采用Evolution型神经肌肉记录仪检测,表面电极直接刺激眶上神经,诱发瞬目反射(blinkreflex,BR)。在同侧眼轮匝肌记录出短潜伏期波(R1)和双侧眼轮匝肌记录出长潜伏期波(R2,R2’)。对20名(40侧)健康人和30例患者(其中包括三叉神经疾病,面神经疾病及听神经瘤)进行瞬目反射测试。结果BR潜伏期健康成人平均值R1为10.1ms,R2和R2’为30.4ms和30.7ms。患者组患侧BR各波潜伏期延长,与健侧和健康人相比较,经t检验,P<0.01,差异有极显著性。结论测试结果表明该技术简单、可靠,对三叉神经、面神经疾病和听神经瘤的早期诊断能提供有价值的电生理测试结果。
Objective To study the normal value and clinical applications of blink reflex. Methods Using the clinical electrodiagnostic techniques , the orbital nerve was stimulated to elicit the blink reflex. Results In 20(40 sides) normal subjects, two components (R 1 and R 2) had been documented . The latencies were about 10.1 ms for R1,30.4 ms and 30.7 ms seperatly for R 2 and R 2'. In 30 patients with trigeminal and facial nerve diseases and acoustic neuromas, the latencies on the affected sides were apparently longer or the reflex disappeared( P <0.01). Conclusion This study indicates that the simple, harmless electrodiagnostic measurements are of value in the initial investigation of trigeminal and facial nerve diseases and acoustic neuroma.
出处
《中华耳鼻咽喉科杂志》
CSCD
1998年第6期347-349,共3页
Chinese Journal of Otorhinolaryngology
关键词
眨眼
三叉神经
面神经疾病
听神经瘤
瞬目反射
Blinking Trigeminal nerve Facial nerve diseases Neuroma, acoustic Adult