期刊文献+

不同螺旋角螺旋折流板换热器传热性能对比实验 被引量:4

Comparison Experimental Study of Heat Transfer Performance of Heat Exchangers with Different Helical Baffles
下载PDF
导出
摘要 对螺旋角为8°、12°1、8°、30°4、0°的螺旋折流板换热器进行了壳程传热性能和压力降测试,得到了相应结构下的总传热系数和压力降。然后通过对试验数据的整理分析,并进行曲线回归,得到了不同螺旋角的螺旋折流板换热器换热系数和压降经验计算公式。研究表明,实验条件下,30°螺旋角的螺旋折流板换热器的单位压降传热系数要优于8°、12°、18°、40°螺旋角的螺旋折流板换热器的传热系数。 Tests of heat transfer performance and pressure drop were conducted for the helical baffle heat exchangers with helix angle of 8°, 12°, 18°, 30° and 40°, and the heat transfer coefficient and the pressure drop were investigated. Through analyzing experimental data, we presented some empirical formulas of shell - side heat transfer coefficient and the pressure drop. Under test conditions, the general heat transfer performance per pressure drop of baffle heat exchanger with helix angle of 30° is better than that of baffle heat exchangers with helix angle of 8°,12°,18° and 40°.
出处 《节能技术》 CAS 2009年第6期519-521,共3页 Energy Conservation Technology
关键词 螺旋角 螺旋折流板 传热系数 换热器 helix angle helical baffle board heat transfer coefficient heat exchanger
  • 相关文献

参考文献4

  • 1王秋旺,罗来勤,曾敏,王良,陶文铨,黄彦平.交错螺旋折流板管壳式换热器壳侧传热与阻力性能[J].化工学报,2005,56(4):598-601. 被引量:33
  • 2Stehlik P,WadekerV. Different Strategies to Improve Industrial Heat Exchanger [J]. Heat Transfer Eineering, 2002,23 (6) : 36 - 38.
  • 3刘巍,梁龙虎,刘云哲.冷换设备设计手册[M].北京:中国石化出版社,2003年.
  • 4[日]幡野佐一.换热器[M].北京:化学工业出版社,1987..