介绍10万t级油码头钢管桩牺牲阳极阴极保护设计及实施情况。实测所有钢桩保护电位均在-901~-1096mV之间(相对银/氯化银/海水参比电极),表明钢桩得到了充分的保护。
The conditions of design and implementation of sacrificial anodes protection for steel pipe pile of 100,000 DWT oil terminal were introduced in the paper. All the potential of protection acually measured are between -901- -1096 mV (the reference pole of relative Ag/Agcl). That shows the steel pipe piles have been protected well.
出处
《港工技术》
北大核心
1998年第4期33-36,共4页
Port Engineering Technology
关键词
牺牲阳极
阴极保护
钢桩
防腐蚀
油码头
sacrificial anodes, cathodic protection, steel pile, anti-corrosion